Rockwell Automation 440P-WA1B Lever with Wide Roller User Manual
Rockwell Automation Equipment

Installation and Operating Instructions
Bulletin 440P-WA1B Lever with Wide Roller
IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.
This publication does not include all specifications, dimensions, or any special installation considerations.
Refer to the product catalog pages for additional information.
General Data
• Designed for 440P-A short lever with wide roller limit
switches
• Nylon roller
• Roller diameter 13.5 mm (0.53 in.) x width 25.4 mm (1 in.)
• Lever radius 25 mm (0.98 in.)
• Lever length 40 mm (1.57 in.)
• Includes lock nut and washer
Principles, Standards, and Implementation
Operating specifications must be followed. Actuators should 
be displaced beyond the point where direct opening action 
occurs. If adjustable actuators become loose they may defeat 
the direct opening action feature of the limit switch. These 
devices are not to be used to directly control a motor.
ATTENTION: To avoid electrical shock and unintended
operation of equipment, disconnect all 
power to the limit switch and the controlled 
equipment before proceeding with any 
repair or adjustment of the limit switch.
IMPORTANT: Installation of Allen-Bradley limit switches should be in
accordance with local and/or national codes. Servicing 
energized industrial control equipment can be hazarous if 
not in accordance to recommended safety procedures.
Lever with wide roller
shown installed.
Dimensions [mm (in.)]
Instructions
1. Mount lever arm on keyed shaft in desired position.
2. Install washer.
3. Install Hex lock nut.
4. Torque Hex lock nut to 1…1.4 N•m (8.85…12.39 lb•in).
ATTENTION: For safety applications
Rockwell Automation recommends 
replacing the complete limit switch.