beautypg.com

Rockwell Automation 160 Low Profile Drive User Manual

Page 3

background image

The following curves show the output ratings of a Low Profile Drive based on input voltage
and duty cycle. Duty cycle is calculated based on a 20 second on-time.
(For example: 25% duty cycle = 20 second on time, 60 second off time).

The heatsink of the 160-L is smaller than the heatsink of the standard Series C 160. The 160-L
can not dissipate heat as effectively as the standard Series C 160.

The purpose of these derating curves is to show how much current the 160-L may carry.

The maximum on time that can be used without 100% duty cycle derating is 20 seconds. To
illustrate how the charts function, consider the following examples:

1. 160-L is on for 1 second and off for 3 seconds, the duty cycle is 25%.

2. 160-L is on for 20 seconds and off for 20 seconds, the duty cycle is 50%.

3. 160-L is on for 40 seconds and off for 120 seconds, the duty cycle is 100%.

IMPORTANT: Since the on time in example 3 exceeds 20 seconds, 100% duty cycle derating
must be used regardless of the off time.

160-AA12L (230V)

Fan Cooled

0

2

4

6

8

10

12

0%

25%

50%

75%

100%

Duty Cycle (20 sec. On time)

Amps

Ambient Temperature 30C

Ambient Temperature 40C

Ambient Temperature 50C

Ambient = 30C

Ambient = 40C

Ambient = 50C