Sensaguard, 18 mm plastic barrel installation instructions 9 – Rockwell Automation 440N SensaGuard 18 mm Plastic Barrel Unique Coded Installation Instructions User Manual
Page 9
PN-46045 10000054879 Ver 00 October 2009
SensaGuard
TM
18 mm Plastic Barrel Installation Instructions 9
Unit Response Time (does not include safety relay response time)
Yel
Red
White
Gray
Pink
Blue
24V DC
Power
Supply
1606
Sensor 1
+24
RT
Sensor 2
Brown
Brown
Gray
Pink
White
Yel
Red
Blue
Sensor 3
Brown
Yel
Red
White
Gray
Pink
Blue
A1
S21
S11
41
33
23
13
S12
S52
42
34
24
14
A2
S34
S22
440R-N23126
Actuator 1
Actuator 2
Actuator 3
Initial Conditions:
All actuators are in sensing
distance.
Actuator 1 is moved out of
sensing range.
Sensor 2 drops the 24 volts
(red and yellow) from Sensor 1
OSSD outputs.
Green LED flashes.
Sensor 3 drops the 24 volts
(red and yellow) from Sensor 2
OSSD outputs.
Green LED flashes.
0 mS
54 mS
72 mS
90 mS
Actuator 1 is out of sensing
range.
Actuator 2 and 3 are in
sensing range.
Actuator 1 is moved into sensing
range.
Sensor 1 OSSD outputs are
energized.
Sensor 2 OSSD inputs (red and yellow)
transition to 24V DC from Sensor 1
OSSD outputs.
Sensor 2 OSSD outputs are energized
Sensor 3 OSSD inputs (red and
yellow) transition to 24V DC from
Sensor 2 OSSD outputs.
Sensor 3 OSSD outputs are
energized.
0 mS
360 mS
378 mS
396 mS
OFF
ON
Note: Refer to Technical Specifications for Certification information and ratings.