Drive Rating

Input/Output Ratings

Environmental Specifications

Parameter

Min / Max Range

Units

Factory Default

P42 - [Motor Overload Current]

2.0 / 4.5

Amps

9.2 Amps

P43 - [Current Limit]

1.6 / 8.0

Amps

12 Amps

IP20 Catalog
Number

Output Ratings

Input Ratings

Dynamic Braking Torque

Power
Dissipation

Three-Phase
Input, 50/60 Hz

kW

HP

Output
Current

Operating
Voltage
Range

kVA

Without
External
Resistor

With 160-BMA1
External Resistor

With 160-BMA2
External Resistor

IP20 (Chassis
Mount)

160-NX3

0.55

0.75

3.0A

180-265V

1.8

100%

233%

366%

11W

Output Voltage

0V to Input Voltage (Adjustable)

Output Frequency

0 to 240 Hz (Programmable)

Efficiency

97.5% (Typical)

Transient Protection

Standard 6kV(Series C drives)

Enclosure

Heatsink meets NEMA Type 4/4X/12 (IP66) requirements.
The drive is an open style (IP20) device.

Ambient Temperature

Internal Enclosure Ambient: 0 to 50 degrees C (32 to 122 degrees F)
External Heatsink Ambient: 0 to 40 degrees C (32 to 104 degrees F)
Maximum Heatsink Temperature: 90 degrees C (194 degrees F)

Storage Temperature

–40 to 85 degrees C (–40 to 185 degrees F)

Relative Humidity

0 to 95% (non condensing)

Vibration

1.0 G Operational - 2.5 G Non-operational

Shock

15 G Operational - 30 G Non-operational

Altitude

1,000 meters (3,300 feet) without derating