Rockwell Automation 440P Bulletin 440P 2 N.C. Small Metal Safety Position Switches, 2 m Cable User Manual
Rockwell Automation Equipment
Installation and Operating Instructions
Bulletin 440P 2 N.C. Small Metal Safety Position Switches, 2 m Cable
IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.
General Data
• Safety contacts: 2 N.C.
• Enclosure rating:
• NEMA 1
• IP66/IP67
• Rugged die cast housing
• 2 m (6.6 ft) prewired cable
• Compact profile for access limited installation
Principles, Standards, and Implementation
Before installation in a safety application, a risk assessment
should be performed to determine whether the specifications
of this device are suitable for foreseeable operational and
environmental characteristics of the machine which is to be
controlled. When applying these limit switches in a safety
system application, all applicable standards for application
should be followed. Operating specifications must be followed
and actuator must be displaced beyond the point where Direct
Opening Action occurs. These devices are not to be used to
directly control a motor.
To avoid electrical shock and unintended operation
of equipment, disconnect all power to the limit
switch and the controlled equipment before
proceeding with any repair or adjustment of the
limit switch.
Installation of Allen-Bradley Guardmaster products
should be in accordance with local and/or national
codes. Servicing energized industrial control equip-
ment can be hazardous if not in accordance with
recommended safety procedures.
ATTENTION
IMPORTANT
Specifications
Safety Ratings
Standards
EN 954-1, ISO 13849-1,
IEC/EN 60204-1, NFPA 79, EN 1088,
ISO 14119, IEC/EN 60947-5-1,
ANSI B11.19 AS 4024.1
Safety Classification
Cat. 1 Device per EN 954-1 Dual channel
limit switch suitable for Cat. 3 or 4
systems
Certifications
cULus Listed, TÜV and CE Marked for all
applicable directives
Outputs
Safety Contacts
2 N.C. snap acting
Thermal Current (/
lth
)
10 A
Rated Insulation Voltage (ui)
300V AC
Short Circuit Protection
10 A max. fast acting fuse IEC 269 type
gG or equivalent
Contact Ratings
Maximum AC Contact Rating Per Pole (50/60 hz) Same Polarity
NEMA Rating
Designation
Max.
Voltage
Amperes
Continuous
Carrying
Current (Amp.)
Voltamperes
Make Break
Make Break
AC15/ B300
120
30
3
5
3600
360
AC15/ B300
240
15
1.5
5
3600
360
Maximum AC Contact Rating Per Pole (50/60 hz) Same Polarity
DC13/ Q300
240
0.27
0.27
2.5
69
69
Operating Characteristics
Actuation Speed, Max.
250 mm/s
Actuation Speed, Min.
100 mm/min
Actuation Frequency, Max.
6000 ops/hr
Mechanical Life
1 x 10
7
operations at room temperature
Environmental
Enclosure Type Rating
NEMA 1, IP66/IP67
Operating Temperature [C (F)]
2…70 ° (35.6…158 °)
Pollution Degree
3
Physical Characteristics
Housing Material
Die cast alloy
Actuator Material
Various polymers and metals
Mounting
2 x M4, any position
Vibration
IEC 68-2-6 (10…55 Hz, 0.35 mm
amplitude)
Shock
IEC 68-2-7 (30 Gn 3 pulses per axis)
Connection
2 m (6.5 ft) cable
Enclosure Color
Red body/black head