Rockwell Automation 160 Line Filter Module 160 Series C User Manual
Page 2
Publication RF-160C-ML – December, 1999
Supersedes July, 1999
Copyright 1999 Rockwell International Corporation. All rights reserved.
Bulletin 160 Line Filter Module Specification Table
Line Filter Module
160S-RFA-9-A 160S-RFA-16-B 160-RFA-22-B
160-RFB-5-A
160-RFB-14-A
160-RFB-14-B
Input Voltage, Frequency
1~ / 200-240 V
3~ / 200-240 V
3~ / 200-460 V
Rated Current
10 A
16.3 A
22 A
5.5 A
14.2 A
14 A
Operational Range (V), (Hz)
180-265 V, 48-62 Hz
180-506 V, 48-62 Hz
Power Dissipation (W)
10 W
6 W
9 W
6 W
12 W
6 W
Leakage Current (Worst Case mA)
Running, Supply Voltage Tol. 3% Acc.
EN 60950 Fault Method
3.5 mA
3.5 mA
3.5 mA
3.5 mA
5 mA
30 mA
5 mA
30 mA
5 mA
30 mA
5 mA
30 mA
Weight (kg)
0.59 kg
1.2 kg
1.3 kg
0.73 kg
0.8 kg
1.2 kg
Enclosure
IP 20
Operating Temperature
0°C to 50°C
Storage Temperature
-25°C to 85°C
Relative Humidity
0 to 90% (Non Condensed)
Vibration
1.0 G Operational – 2.5 G Non-Operational
Shock
15 G Operational – 30 G Non-Operational
Altitude
1,000 m (3,300 ft) Without derating, consult factory for derating information.
EMC Standards
EN 61800-3, EN 50081-1 AC Mains (Residential and Commercial Environment)
Limits equivalent to EN 55011 Class B, Group 1
International Standards and Approvals
CE Low Voltage Directive
Residential, commercial, and light industry. Tested with a maximum motor cable length of 25 m at 4 kHz carrier frequency. Practical results may
differ.
Line Filter Module
A
B
C
D
E
F
G
H
160S-RFA-9-A
182
(7.17)
75.0
(2.95)
37.5
(1.47)
163.0
(6.42)
60.0
(2.36)
M4.5 x 6.5
(0.18 x 0.26)
obround hole
(2 places)
M4.5 x 6.5
(0.18 x 0.26)
obround hole
(2 places)
200
(7.87)
160-RFB-5-A
160-RFB-14-A
182
(7.17)
75.0
(2.95)
47.5
(1.87)
163.0
(6.42)
60.0
(2.36)
160S-RFA-16-B
227
(8.94)
87.0
(3.43)
55.5
(2.18)
212.0
(8.35)
60.0
(2.36)
M4.5 (0.18) slot
(2 places)
M4.5 (0.18)
(2 places)
160-RFA-22-B
160-RFB-14-B
B
E
C
A
D
F (2)
H
160-RFA
160-RFB
160 SSC
L1 L2 L3
R
L1
S
L2
T
L3
T1
U
T2
V
T3
W
L1' L2' L3'
M
G (2)