Rockwell Automation 500 NEMA Non-Combination Starter Accessories for Field Installation User Manual
Page 2
Section 2: Voltage Control Accessories
Catalog Number
80VA, 208V Primary / 120V Secondary, 60 Hz
80VA, 240V Primary / 120V Secondary, 60 Hz
80VA, 480V Primary / 120V Secondary, 60 Hz
80VA, 600V Primary / 120V Secondary, 60 Hz
200VA, 208V Primary / 120V Secondary, 60 Hz
200VA, 240V Primary / 120V Secondary, 60 Hz
200VA, 480V Primary / 120V Secondary, 60 Hz
200VA, 600V Primary / 120V Secondary, 60 Hz
250VA, 208V Primary / 120V Secondary, 60 Hz
250VA, 240V Primary / 120V Secondary, 60 Hz
250VA, 480V Primary / 120V Secondary, 60 Hz
250VA, 600V Primary / 120V Secondary, 60 Hz
350VA, 208V Primary / 120V Secondary, 60 Hz
350VA, 240V Primary / 120V Secondary, 60 Hz
350VA, 480V Primary / 120V Secondary, 60 Hz
350VA, 600V Primary / 120V Secondary, 60 Hz
Transformers with Top Mounted Fuse Block Standard Capacity
0-2
0-2
0-2
0-2
3
3
3
3
4
4
4
4
5
5
5
5
NEMA Starter Size
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
1497-N1PK
1497-N2PK
1497-N2PK
1497-N3PK
1497-N4PK
1497-N5PK
1497-N5PK
1497-N6PK
1497-N7PK
1497-N8PK
1497-N8PK
1497-N9PK
1497-N10PK
1497-N11PK
1497-N11PK
1497-N12PK
130VA, 208V Primary / 120V Secondary, 60 Hz
130VA, 240V Primary / 120V Secondary, 60 Hz
130VA, 480V Primary / 120V Secondary, 60 Hz
130VA, 600V Primary / 120V Secondary, 60 Hz
250VA, 208V Primary / 120V Secondary, 60 Hz
250VA, 240V Primary / 120V Secondary, 60 Hz
250VA, 480V Primary / 120V Secondary, 60 Hz
250VA, 600V Primary / 120V Secondary, 60 Hz
350VA, 208V Primary / 120V Secondary, 60 Hz
350VA, 240V Primary / 120V Secondary, 60 Hz
350VA, 480V Primary / 120V Secondary, 60 Hz
350VA, 600V Primary / 120V Secondary, 60 Hz
500VA, 208V Primary / 120V Secondary, 60 Hz
500VA, 240V Primary / 120V Secondary, 60 Hz
500VA, 480V Primary / 120V Secondary, 60 Hz
500VA, 600V Primary / 120V Secondary, 60 Hz
100 Watt Extra Capacity
0-2
0-2
0-2
0-2
3
3
3
3
4
4
4
4
5
5
5
5
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
All
1497-N15PK
1497-N16PK
1497-N16PK
1497-N17PK
1497-N7PK
1497-N8PK
1497-N8PK
1497-N9PK
1497-N10PK
1497-N11PK
1497-N11PK
1497-N12PK
1497-N18PK
1497-N19PK
1497-N19PK
1497-N20PK
(2)
Enclosure Type
Fuse Block Kits For Separate Control
Primary Fuse Block - Panel Mount Only, 2-Pole (30A /600V)
Secondary Fuse Block - Panel Mount Only, 2-Pole (30A /600V)
0-5
0-5
All
All
1491-R162
1491-R167
Fuse Blocks
Primary Fuse Block - Panel Mount Only, 3-Pole (30A /600V)
0-5
All
1491-R171
Control Circuit Fusing Kits
Single fuse holder. Contactor Mount 6A/ 600V
0-5
All
599-FR04
One Block
0-5
All
1491-R150
Fuse Cover (NOTE: One cover per pole is required. Example: Transformer with top mounted fuse block requires (3) covers.
Fuse block kit for separate control requires (2) covers.
Section 3: Overload Relay Accessories
23…75 A
66…110 A
57…180 A
96…300 A
All
All
All
All
592-A2KE
592-A2LE
592-A2ME
592-A2NF
4
4
4
5
23…75 A
66…110 A
57…180 A
96…300 A
All
All
All
All
592-A5KE
592-A5LE
592-A5ME
592-A5NF
4
4
4
5
EC1 and EC2 Solid State Overload Relays
NOTE: EC1 and EC2 models offer field selectable trip class.
EC1 - 2 Inputs
1 Output
1…5
3…15
5…25
9…45
All
All
All
All
592-EC1AC
592-EC1BC
592-EC1CC
592-EC1DC
0-1
0-1
2
2
EC2 - 4 Inputs
2 Outputs
1…5
3…15
5…25
9…45
All
All
All
All
592-EC2AC
592-EC2BC
592-EC2CC
592-EC2DC
0-1
0-1
2
2
Nema Starter Size
SMP-1 Class 20 Automatic/Manual Reset (NOTE: The following Catalog
Numbers represent Class 20 Overload Relays. To order Class 10 change
prefix from A5 to A4. To order Class 30 change prefix from A5 to A6)
SMP-1 Class 20 Manual Reset (NOTE: The following Catalog Numbers
represent Class 20 Overload Relays. To order Class 10 change prefix from
A2 to A1. To order Class 30 change prefix from A2 to A3)
Catalog Number
Enclosure Type
0.2…1.0 A
1.0…5.0 A
3.2…16 A
5.4…27 A
9…45 A
9…45A
18...90A
All
All
All
All
All
All
All
592-EEBC
592-EECC
592-EEDC
592-EEEC
592-EEFC
592-EEFD
592-EEGD
0
0
0
1
2
2
3
Nema Starter Size
E1 Plus Solid State Overload Field Selectable Trip Class (10, 15, 20, 30)
and Manual / Auto Reset
Catalog Number
Enclosure Type
One Normally Open 1 N.O.
One Normally Closed 1 N.C.
One Normally Open 1 N.O.
One Normally Closed 1 N.C.
Auxiliary Contact
For Eutectic Alloy Overload Relays
0-2, 5-6
0-2, 5-6
3-4
3-4
All
All
All
All
595-A02
595-B02
595-A34
595-B34
NEMA Starter Size
Catalog Number
Enclosure Type
23…75 A
66…110 A
57…180 A
96…300 A
All
All
All
All
592-B1KE
592-B1LE
592-B1ME
592-B1NF
4
4
4
5
Catalog Number
Nema Starter Size
SMP-2 Solid State Overload Relays
(NOTE: SMP-2 models offer field selectable trip
class)
Enclosure Type
PN-63837
DIR 10000084748 (Version 00)