Dimensions—mm (inches)
17
(0.669)
13.5
(0.531)
10.5
(0.413)
13
(0.511
)
Set
Self Teach
+
3
+
2
+
1
Light
-
1
4
(0.157)
4
(0.157)
56
(2.204)
9
(0.354)
2
(0.078)
3
(0.118)
6.7
(0.263)
3
(0.118)
9
(0.354)
47
(1.850)
35.3
(1.389)
9
(0.354)
4.5
(0.177)
Dia. 3.2 x 3.6
(0.126 x 0.142) 2 Places
12
(0.472)
Cable Clamp
Normal/Off
Delay Switch
Light Operate/Dark
Operate Switch
Mode Switch (Run, Set,
Auto, Hysteresis, Sensitivity)
Light Level
(Margin) Indicator
Set Indicator (Flashes During
Automatic Sensitivity Setting)
Self Teach Button
(Steps Sensitivity or Hysteresis Up or
Down Depending on Mode Switch
Selection)
13.5
(0.531)
34
(1.338)
Visible Red, Green, or Blue Fiber Optic
Output Characteristics
Operating
Voltage
Supply
Current
Output
Energized
Type
Max Load
Current
Max Leakage
Current
Response
Time
Emitter LED
Catalog Number
Red
42FT-F2LPA-A2
Red
42FT-F2LPA-Y3
60mA
PNP
Green
42FT-F3LPA-A2
60mA
PNP
Green
42FT-F3LPA-Y3
Output:
Blue
42FT-F6LPA-A2
12-24V DC
Light/Dark
Output:
100mA
0 5mA
500 s
Blue
42FT-F6LPA-Y3
12-24V DC
±
10%
Light/Dark
Selectable
100mA
Stability:
50mA
0.5mA
500
µ
s
Red
42FT-F2LNA-A2
y
50mA
Red
42FT-F2LNA-Y3
50mA
NPN
Green
42FT-F3LNA-A2
50mA
NPN
Green
42FT-F3LNA-Y3
Blue
42FT-F6LNA-A2
Blue
42FT-F6LNA-Y3
Typical Glass Fiber Optic Cable Selection—mm (in)
LED
Sensing Mode
Plastic
Fiber
Diameter
Typical
Fiber
Model
MaxiĆ
mum
Range
Diffuse
1 (0.040)
99-94
110 (4.3)
Red
Diffuse
(Bifurcated Fiber)
0.5 (0.020)
99-808
30 (1.2)
Red
Transmitted Beam
1 (0.040)
99-90
350 (13.2)
Transmitted Beam
(Individual Fiber)
0.5 (0.020)
99-822
95 (3.7)
Green
Diffuse
(Bifurcated Fiber)
99-94
13 (0.5)
Green
Transmitted Beam
(Individual Fiber)
1 (0 040)
99-90
35 (1.4)
Blue
Diffuse
(Bifurcated Fiber)
1 (0.040)
99-94
18 (0.7)
Blue
Transmitted Beam
(Individual Fiber)
99-90
60 (24)
Mode Switch
AUTO (Factory Setting)
Allows Self-Teach to be initiated with the pushbutton on the
sensor (Local) or through an external connection (Remote).
Sensor indicators and outputs are active and function normally.
Sensors may be operated in AUTO mode. Sensors must be
operated in AUTO mode when Remote Self-Teach is required.
SET
Allows self-teach to be initiated with the pushbutton on the
sensor (Local) only. The external Self-Teach connection
(Remote) is ignored. Sensor indicators function normally. Both
sensor and stability outputs are inhibited.
RUN
RUN mode is recommended for sensor operation in all
applications where Remote Self-Teach will not be used.
Sensor indicators and outputs are active and function normally.
No adjustments, Local or Remote, are possible while the
sensor is in RUN mode.