Step 5: remove the existing bimetal thermostat, Step 6: install the new bimetal thermostat – Rockwell Automation 20P PowerFlex DC Drive - Frame A Bimetal Thermostat User Manual
Page 10
10
PowerFlex® DC Drive - Frame A Bimetal Thermostat
Step 5: Remove the
Existing Bimetal Thermostat
Remove the two screws that secure the thermostat to the drive heat sink and
remove the thermostat and connected wires from the drive.
Step 6: Install the New
Bimetal Thermostat
• Install the Bimetal Thermostat in reverse order of removal as detailed in
Remove the Existing Bimetal Thermostat
above.
Important: Thermal grease must be applied to the bottom of the Bimetal
Thermostat before securing it to the heatsink.
Step 7: Install the Pulse
Transformer Board and
Switching Power Supply
Board
• Install the Pulse Transformer board and Switching Power Supply board
in reverse order of removal as detailed in Step 4:
Transformer and Switching Power Supply Boards on page 5
Step 8: Install the Control
EMI Shield and Control
Board
• Install the Control EMI Shield and Control board in reverse order of
removal as detailed in Step 3:
Remove the Control EMI Shield and
.
Remove screws
ATTENTION: Each gate lead cable must be connected to the
exact connector from which it was removed on the Pulse
Transformer circuit board or damage to the drive may occur.