Wiring diagrams, 3approximate dimensions [mm (in.), Downstream connection (discharge end) – Rockwell Automation 44N Zone Control Photoelectric Sensors User Manual
Page 3: Female, Male, Upstream downstream
![background image](/manuals/576905/3/background.png)
3
Approximate Dimensions [mm (in.)]
55.62 (2.19)
74.93
(2.950) Ref
31.75
(1.250)
40 (1.575)
32.66 (1.286)
M30 x 1.5 external
thread 1/2 in. NPSM
internal thread
5.21 (0.205) x
8.13 (0.320)
Slot, 2 Places
5.46 (0.215)
15.87 (0.625)
41.91
(1.65)
30.35
(1.195)
103.63 (4.08)
Max. Travel
304.88 mm (12 in.) cable on 44NSP--2JPBD--Z01. Female right angle pico (M8) QD on a
533.4
mm (21 in.) cable on 44NSP--2JPBD--Z02 and 44NSP--2JPBD--Z03.
Refer to page 1 for downstream and upstream cable lengths.
ZONE 4
ZONE 3
ZONE 2
ZONE 1
valve
P4
P3
P2
P1
Direction of Product Flow
valve
valve
valve
Upstream Connection
Downstream Connection
Wiring Diagrams
Female
(Pin 1)
Blu
e
( + )
( -- )
Male
(Pin 2)
(Pin 4)
(Pin 3)
(Pin 1)
(Pin 2)
(Pin 4)
(Pin 3)
Slug
Singulation
( + )
( -- )
Slug
Singulation
2
1
Bro
wn
Upstream
Downstream
Output load 30V DC
100 mA, PNP
Product comes with 22 AWG cable.
3
2
4
1
3
4
1
2
5
Downstream Connection (Discharge End)
For Singulation Release:
To activate the singulation release signal connect pin 4 (black
wire using an 889D--F4BC--2 cable) to +24V DC. The
discharge zone will singulate as long as the singulation
release signal is active.
For Slug Release:
To activate the slug release signal connect pin 2 (white wire
using an 889D--F4BC--2 cable) to +24V DC. All the zones will
drive simultaneously without singulating (separating) the
boxes.
Upstream Connection (Infeed End)
The 44N Zone Control sensor allows the user to monitor the
status of the infeed zone by using an 889D--M4BC--2 male
cordset connected to the upstream connection of the infeed
sensor.
The black wire of the 889D--M4BC--2 cordset provides this
signal. A voltage signal indicates that there is no object
blocking the infeed zone. A 0V DC signal indicates that the
infeed sensor is blocked.
The upstream connection output current is limited by a 3 k
Ω
resistor, which would allow the sensor to drive certain I/O
cards. Rockwell Automation recommends the following I/O
cards for reliable output detection.
1769--IB16I
1756--IB32
1756--IB16
1769--1Q32
1769--1Q16