12. Remove the appropriate gate leads:

For non-regenerative drives, remove each pair of (orange and yellow)

gate lead cables from connectors KG01…KG06 and push each lead
through the appropriate opening in the board.

For regenerative drive, remove each pair of (orange and yellow) gate

lead cables from connectors KG01…KG06 and KG1…KG6 and push
each lead through the appropriate opening in the board.

Important: Carefully remove the gate leads by grasping the connector.

DO NOT pull the gate leads off by pulling on the wires.

For non-regenerative
drives, remove six gate
leads and route
through openings in
board

For regenerative
drives, remove 12 gate
leads and route
through openings in
board