INSTALLATION INSTRUCTIONS

FOR WARMLYYOURS CUSTOM MATS

WARNING

READ ALL OF THE INSTRUCTIONS BEFORE BEGINNING INSTALLATION. FAILURE TO OBSERVE
THE WARNINGS COULD RESULT IN DEATH OR INJURY FROM ELECTRICAL SHOCK OR FIRE. MAT
FAILURE, IMPROPER OPERATION OR FLOOR DAMAGE MAY ALSO BE A RESULT. A MAT WARRANTY
IS PROVIDED (PER NOTED TERMS) BASED ON THE INSTALLATION BEING DONE IN ACCORDANCE
WITH THESE INSTRUCTIONS. IMPROPER INSTALLATION MAY VOID WARRANTY.

Inspection

Electrical inspection may be required during and or after heating mat installation. BEFORE BEGINNING INSTALLATION
contact your local electrical and building inspection authorities for more information. Local codes may require this mat and/
or the thermostatic control to be installed or connected by an electrician. WarmlyYours requires all electrical connections
be made by qualifi ed personnel and in accordance with the National Electrical Code (NEC) or National Electrical Code
(NEC) and all applicable local codes and ordinances.

Application

The WarmlyYours mat has been designed to warm hard surface materials such as ceramic and porcelain tiles, marble,
granite, slate, laminate and engineered wood fl ooring. WarmlyYours mats are designed for use inside residential and light
commercial buildings.

DO NOT use the WarmlyYours custom mat for applications other than for embedded indoor fl oor warming.
DO NOT use the WarmlyYours custom mat with carpet, solid wood, linoleum or vinyl fl oors.
DO NOT energize the WarmlyYours custom mat until it is embedded in thinset masonry and the masonry has cured per

manufacturer’s recommendations.

DO NOT cut or modify the WarmlyYours custom mat to fi t the area.
DO NOT overlap WarmlyYours custom mats.
DO NOT use staples to hold or secure the cold lead or thermostat sensor wire.
DO NOT attempt to repair a damaged heating mat, call WarmlyYours for instructions before proceeding further.
DO NOT unroll and install mat when it is colder than 0C (32F).
DO NOT cross construction or expansion joints.

WarmlyYours custom mats provide comfort warming. WarmlyYours custom mats are approved to standard C22.2 No
130-03 and carry a –X rating, suitable for indoor embedded fl oor surface heating, dry locations. Residential kitchens,
basements and bathrooms (not shower areas) are considered dry locations. WarmlyYours mats must be connected to a
ground fault protection device. WarmlyYours “TH” series thermostats include ground fault protection, if this thermostat is
not used the mat must be connected through a separate ground fault protection device.