beautypg.com

Vicor DC MegaPAC DC-DC Switcher User Manual

Page 15

background image

DC MegaPAC Operator’s Manual

Rev. 3/04

Vicor 800-735-6200 Mission Power Solutions (760) 631-6846 (phone) or (760) 631-6972 (fax)

Pg. 15

Specifications

Input Characteristics

Input Voltage

12 Vdc (10-20), 24 Vdc (18-36), 36 Vdc (21-56),

48 Vdc (36-76),

72 Vdc (55-100)

Power Factor

1.0

Line Regulation

0.2% max. from 10% to full load

Inrush Current

5A peak @ 48 Vdc input

Conducted EMI

BTR 2511

Issue 4

Transient Surge

EN/IEC 1000-4-2 Level 4

Output Characteristics

Load Regulation

0.2% max. from 10% to 100% load

0.5% max. from 0% to 10% load

Setpoint Accuracy

1% for standard voltages

2% for special or adjustable voltages

Ripple and Noise

Std. outputs: 2% or 100 mV p-p max., whichever is greater, 10% min. load

VXI options (

<

24V outputs): 50 mV p-p max for outputs

<

15 Vdc;

150 mV p-p max. for 24 Vdc outputs

QPAC, DualQPAC, JuniorPAC, RAMPAC: <10mV p-p max.

Overcurrent Protection

105-130% > 5V outputs & DualPACs, JuniorPACs, RAMPACs, DualQPACS,

JuniorQPACs

30-125%

<

5V outputs

Overvoltage Protection

ModuPACs and QPACs: 115-135%

N/A to DualPACs, JuniorPACs, BatPACs, RAMPACs, DualQPACs and

JuniorQPACs

Efficiency

83% typical

Output Power

1600W @ 45°C (Output power dependent upon Input voltage)

Environmental Characteristics

Storage Temperature

-40°C to +65

°C

Operating Temperature

C-grade: 0

°C to +45°C full power, 0°C to +65°C half power

I-grade: -20

°C to +45°C, -20°C to +65°C half power

See temperature derating curves.

Safety Approvals

UL 1950 (2nd), CSA C22.2 No. 234, IEC 950, EN 60 950

Product Weights

9.25 lbs (4,2 kg) fully configured

0.7 s (0,32 kg) ConverterPAC

Warranty

1 year

Humidity

0-95% noncondensing

Altitude

15,000 feet maximum. Derates linearly.