beautypg.com

Pfc micros™ power factor corrected ac-dc switcher – Vicor PFC MicroS Power Factor Corrected AC-DC Switcher User Manual

Page 3

background image

03-000049 rev A

Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474 Pg. 3

PFC MicroS™
Power Factor Corrected AC-DC Switcher

Overview

The PFC MicroS is an ultra low profile switching power supply that combines the advantages of power factor cor-
rection (PFC) with high power density. This guide covers both the standard and rugged COTS (MI) versions of the
supply. The PFC MicroS provides up to 3 isolated outputs (from 1 slot) and accommodates the following Vicor
DC - DC Converters:

VI-200/VI-J00: 1 full brick or 2 half brick
Maxi/Mini/Micro: 1 full brick, 2 half bricks or 3 quarter bricks

The use of these converters give the PFC MicroS the inherent power flexibility typical of all Vicor products.
Accepting input voltages of 85 Vac to 264 Vac, and 100 to 300 Vdc, the PFC MicroS can provide up to 600 Watts
in a package size of 1.86" H (47.mm) x 5.06" W (128,5mm) x 7.95" L (201,9mm). The PFC MicroS is factory con-
figured to meet output requirements of the user. Using the VSPOC configurator tool available on vicorpower.com,
anybody can now configure a PFC MicroS (and other Westcor power supplies) online.

Standard Features

• Power Factor Correction: Typically 0.98 (>75% Load)
• Universal Input: 85-264 Vac, 47-500 Hz, or 120-300 Vdc
• Power Output: 600W at 230 Vac (200 Vac minimum input) ; 500W at 115 Vac (100 Vac minimum input)
• Up to 3 isolated outputs (1 slot)
• Fan

cooled

• Full power to 45°C; half power at 65°C
• Soft start for limiting inrush current
• Conducted EMI:

FCC Class A
EN 55022, Class A (consult factory)

• Harmonic Distortion to EN61000-3-2
• AC Power OK status signal;
• Output Sequencing and General Shutdown

Autosense (Refer to page 6 and 11 for more information on Autosense)

• Output overcurrent protection on all outputs
• Output overvoltage protection (not applicable when using VI-J00 DC-DC Converters)
• Output overtemperature limiting

(not applicable when using VI-J00 DC-DC Converters )

• Ride-through (holdup) time: >20 ms at 500W load (nominal line)
• Size: 1.86" H (47,3mm) x 5.06" W (128,5mm) x 7.95" L (201,9mm)

Safety Agency Approvals: CE Marking, TUV CUE. (certain configurations may not have all listed approvals)

Uses 300 Vdc input VI-200/VI-J00 modules and/or 375 Vdc input Maxi/Mini/Micro modules

Power good status signal when Maxi, Mini or Micro modules used

Optional Features

I/T/H-grade output converters

Current Share Board for unit to unit power sharing- See page 18 and 19

Connector kits (#19-130044)

MI Chassis specific options:

Mil-STD 810 for Shock and Vibration

Mil-STD 704 and 1399 for Overvoltage and Transients

-40oC operation

Conformal coating - contact factory

PFC MicroS Design Guide