beautypg.com

Vicor PFC MicroS Power Factor Corrected AC-DC Switcher User Manual

Page 16

background image

PFC MicroS Design Guide

O

UTPUT

(

CONT

D

.)

Maxi/Mini/Micro Modules

Parameter

MIN.

TYP.

MAX.

UNITS

NOTES

Setpoint Accuracy*

±0.5

±1

% of V

NOM

Load/line Regulation

±0.08

±0.45 ( ±7)

% of V

NOM

0% to 100%

Temperature Regulation

0.002

0.005

%/°C

-20 to 100°C

Long Term Drift

0.02

%/K hours

Output Ripple and noise:

10V out

100

mV

20 MHz bandwith

> 10 V out

1.0

% Vout

20 MHz bandwidth

Voltage Trim Range

Maxi/Mini/Micro Slots

10-110

% Vout

Preload may be required.

Total Remote Sense Compensation

0.5

Volts

Autosense. See pg.6 & 11

OVP Set Point

112

135

% of V

out

Recycle power

Current Limit

102

115

135

% of I max

Auto Recovery

Overtemperature Limiting

Not available

* For special, adjustable voltages and 48Vdc outputs, maximum setpoint accuracy is 2% of Vnom.

Note: See individual module datasheets for specific module specifications.

E

NVIRONMENTAL

Storage Temperature

-40°C to +85°C

Operating Temperature

Full Power

-20°C to +45°C (-40oC to +45oC option with MI chassis)

Half Power

-20°C to +65°C (-40oC to +65oC option with MI chassis)

Specific temperature data on all module configurations can be obtained by contacting Applications Engineering.

Shock and Vibration (MI chassis only)

Mil-STD-810

Altitude

Derate 2.6% total output power for each 1,000 ft to a maximum
operating altitude of 15,000 ft. Non-operating storage maximum
altitude is 40K.

Humidity

0 to 95% non condensing

Product Weight

3.1 lbs. (1,4 kgs)

Dimensions

1.86" H (47,3mm) x 5.06" W (128,5mm) x 7.95" L (201,9mm)

Warranty**

2 years limited warranty. See vicorpower.com for complete
warranty statement.

** Opening, repairing or modifying the unit will void the warranty. If you have any problem with the power sup-
ply, please contact Customer Service at 1-800-735-6200. If the unit needs to be returned for inspection/analy-
sis, an RMA number will be issued. All units must have a RMA number prior to return.

Pg. 16

Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474

03-000049 rev A