Timer
Timer settings are as follows:
99.99S
999.9S
9999S
99 min 595
99.99 min
999.9 min
9999 min
99h 59 min
99.99h
999.9h
9999h
The curing time required can be set by adjusting the setting from 0 to 999 e.g. 999.1S = 99.9 seconds
or 1.1m = 1/10 minute = 6 seconds
To change the time on the timer, press any of 4 keys A corresponding to each digit.
If the time rang needs to be altered e.g. from seconds to minutes.
First press the valid and mode keys together, then press any key A, this will change the time rang.
Once the appropriate range has been selected press the valid key, and this will return the timer to its
normal display.
The timer mode is pre-set. If for any reason the mode has been changed, the following procedure
needs to be taken.
i)
Press valid and mode keys together
(Puts timer into time range)
ii)
Press the mode key
(Puts timer into count up or down mode)
iii)
Press any A until d is shown on display for count down.
iv)
Press mode key
(Puts timer into operating mode)
v)
Press any key A until H out mode is shown on the display.
vi)
Press valid key to return timer to the normal display.