beautypg.com

Talos Security CT330S CCTV Tester User Manual

Page 11

background image

CCTV Tester User’s Manual

 

 

11 

 

• SYNC SIGNAL means the voltage of the synchronic signal; user can use this

signal to evaluate the impedance of coaxial cable. For example, if the
synchronic signal number of camera is 0.3V (tested by tester in the camera side),
after a long distance transmission via coaxial cable, the synchronic signal
number falls to 0.21V (tested again by tester ), this means the attenuation of
video signal via this coaxial cable is 30%. User can evaluate if the quality of
coaxial cable is good enough for this distance’s usage.

• If there is no signal is detected, “No Video” will be displayed.

3.7 Screen brightness adjustment

At the mode of video and PTZ testing, user can press the num-button “7”BR+and

“9” BR-

) to adjust the brightness of screen.

3.8 UTP cable test

A.

Connect the tester to the UTP cable tester as the picture shows:

B.

In the main menu mode, press num-button “3” to switch to the UTP testing mode;

C.

Press Set to start the test; UTP cable information will be displayed in the screen.

D.

User can estimate the UTP cable connection situation from the information.

——>

UTP tester side sequence

——>” 0”meansopen circui

t

<——

——>

CCTV
Tester
side
sequence

If there are 2 line show “0”, it maybe:

They open circuit separately;

They short circuit to each other;

E.

User can estimate the connect situation based on the information;

F.

Press Menu button for 1 second to back to the main menu.