Page 5

Door open time (seconds)

1. Take the 'door open time' card from the starter pack.

2. Present the card to the reader. The reader will start beeping.

3. Wait for the required period you wish the door to remain open.

4. Present the card again at the end of the period to set the open time. The beeping will stop.

1

2

3

4

BEEP!

BEEP!

FUNCTION CARD

door open time card

The period that the door is unlocked for when a
valid token is presented is set as follows:

1. Present this card
2. Wait for the required period
3. Present this card again, the beeping will stop

FUNCTION CARD

door

open time card

The

period

that

the

doo

r is

unlocked fo

r when

a

va

lid token

is p

resente

d is set as follo

ws:

1.

Present t

his

card

2.

Wait

for the required

pe

riod

3.

Present this

card again

, the

bee

ping

will stop

FUNCTION CARD

door open time

card

The pe

riod that

th

e door is

unlocked f

or

when

a

va

lid token

is presented

is

set a

s follows:

1.

Prese

nt th

is

card

2.

Wait

for

th

e required

period

3.

Present thi

s ca

rd agai

n, the

beeping will

stop

Silent operation

1. Take the silent operation function card from the starter pack.

2. Present the card to the reader. The reader will beep.

3. The reader is now in silent operation mode.

4. Present the card again to disable silent operation mode. The reader will beep twice.

The external handle is only engaged once access has been granted. The inside handle is always engaged.

A valid user card will cause the Green LED to flash briefly and the handle will then engage. This time

period can be changed with the 'door open time' card but should be kept to a minimum to preserve

battery life.

Normal Operation

Alarm Sounder

The alarm is activated when the door fails to re-lock itself. The alarm will sound for 60 seconds during

which time the unit will try to lock the door once every 10 seconds. After 60 seconds the unit will then

shut down. When the unit is woken up, it will immediately try to lock the door. If it fails, the alarm cycle

will start again. Failure to relock will substantially reduce battery life.

1

2

3

4

BEEP!

BEEP!

BEEP!

FUNCTION CARD

silent operation

Present this card to silence the beeping noises
made by the reader. Present this card again to
re-enable the beeping noises

FUNCTION CARD

silent operation

Presen

t this

card to

sile

nce the be

eping noises

made

by

the reader

. Present

this ca

rd

again to

re-enable the be

eping noises

FUNCTION CARD

silent operation

Pre

sent

th

is

card to s

ilence the

beepin

g noises

made by

the

reader

. Presen

t this card a

gain

to

re-e

nable the beeping

noises

Red flash

Amber constant flashing

A valid user card has been presented and the handle is engaged

An invalid user card has been presented - No access granted

LED indications

Green flash

Then unit is configuring - Please wait.