Suitability, Cable extensions, Wiring – Paxton PROXIMITY marine reader User Manual
Page 2: Connection modules, Led indications
Readers mounted together
between
readers
300mm
Mounted on metal surface
Suitability
Security-sensitive doors
Wet environments
Cable extensions
Readers can be extended using Belden CR9540 10-core overall screened cable to a maximum of 100 metres.
Wiring
The reader port module is designed to convert the
standard reader ports on Switch2 and Net2 controllers
to accept one or two RJ45 connections. Pull off the
screw terminal block from the reader port and simply
replace it with this module.
This module can be used to provide a
connection point for the reader RJ45 plug.
The terminals on the module are then wired
colour for colour to the controller.
Alternatively, the reader can be wired directly
into the screw terminals of the control unit by
first cutting off the RJ45 plug and stripping
back the wires in the cable.
Reader port module (325-030)
This module may be purchased separately to speed up
the installation and replacement of readers.
Connection modules
Further information on how to purchase Installer Tools is available at:
http://paxton.info/841
IMPORTANT: This reader cannot be connected
in parallel with other readers and keypads.
Reader junction box (325-020)
Connection to a control unit
reader port
The marine reader has NO Amber LED indication.
Blue - Normal mode (waiting for card)
Green flashing - Access Permitted
Red flashing - Access Denied
Card + PIN - Not supported
Switch 2 - Colour zoning. With only a single colour indication available, active/barred colour zones
cannot be displayed. The reader retains the display selected by the previous user card. Presenting a
valid card leaves the reader green, presenting a card for a disabled colour zone leaves the reader red.
LED indications