Specifications, Using an entry confirmation button – Paxton OEM PROXIMITY Long range reader - EM4100 - Wiegand Output User Manual
Page 5
11V DC
14V DC
1 A
11V DC
14V DC
80 mA
119 kHz
140 kHz
2.405 GHz
2.480 GHz
26 bits
Belden 9540
100 m
0.75 mm sq
mm sq
2.5 mm sq
5000 mm
2000 mm
P200
2500 mm
P50
1100 mm
- 20 °C
+ 55 °C
IPX67
220 mm
220 mm
120 mm
Specifications
Voltage - Reader module
Wiegand format
Carrier frequency
Operating temperature
Electrical
Environment
Dimensions
Min
Max
Width
Height
Depth
Current - Reader module
P200E metal mount
Cable type for extensions
Cable length between ACU and reader
Read range with hands free token
Waterproof
Additional power supply required
Outdoor Use
Button confirmation input
Yes
Yes
Long range reader
Min
Min
Max
Max
Using an entry confirmation button
Where two door readers may pick up the same hands free token, a push to make button can be used to confirm
an entry request for the specific door. Where fitted, the button LED will flash for 5 seconds after the hands free
token has been recognised and must be pressed to unlock the door.
To enable the use of an entry confirmation button do the following steps:
1. Power down the interface board
2. Power up the interface board
3. Press and hold the entry confirmation button for a minumum of 3 seconds within 60 seconds of power up.
To disable the use of the button, repeat the above process.
Voltage - Interface module
Current - Interface module
12V Power cable core diameter - up to 5 m run
12V Power cable core diameter - up to 100 m run