B-10
CONSTRUCTION / DImENSIONS
material
mm
inches
center conductor
solid SPC
(1)
0.29
0.011
dielectric
solid PTFE
(2)
0.84
0.033
inner shield
SPC braid
1.27
0.050
outer shield
SPC braid
1.60
0.063
jacket
brown FEP
(3)
2.10
0.083
ElECTRICal ChaRaCTERISTICS
characteristic impedance
50Ω ± 2Ω
operating frequency range
DC - 3 GHz
shielding effectiveness
80 dB
voltage withstanding
3 000 V rms
peak power
1.8 kW
capacitance
105 pF / m
32 pF / ft
velocity of propagation
69 % (4.8 ns / m)
mEChaNICal ChaRaCTERISTICS
recommended minimum
bending radius
12.5 mm
0.49 inch
weight
12.5 g / m
0.0083 Ibs / ft
ENVIRONmENTal ChaRaCTERISTICS
operating temperature range
-90 / +200 °C
-130 / +392 °F
fire resistance
yes (UL94V0)
halogen free
no
fREqUENCy / aTTENUaTION (typ.) /
CW maX pOWER (sea level / 40 °C)
GHz
dB / m
dB / ft
Watts
0.1
0.42
0.13
253
0.2
0.59
0.18
179
0.3
0.72
0.22
146
0.5
0.94
0.28
113
1.0
1.34
0.41
80
1.5
1.65
0.50
65
2.0
1.92
0.58
57
2.5
2.16
0.65
51
3.0
2.37
0.72
46
attenuation calculation (dB/m)
(1.30 x √f GHz) + (0.04 x f GHz)
power calculation (W)
80 / √f GHz
(1)
SPC = Silver Plated Copper
(2)
PTFE = PolyTetraFluoroEthylene
(3)
FEP = Fluorinated Ethylene Propylene
Due to its small diameter this cable will be
used for applications requiring flexibility.
Its low bending moment allows an easy
routing during installation.
The double braid provides a higher level of
shielding in comparison with 2mm single
braided cables.
In addition the solid inner conductor allows a
very good attenuation level.
The insulation and jacket materials allow this
cable to be used in severe thermal conditions.
APPLICATION NOTE
Cable assemblies
flEXIblE CablE 2/50 D
(124416 type)
p/N: C291 146 087
Note: typical attenuation for a couple of connectors (dB) = 0.045 x √f (GHz)
CONSTRUCTION / DImENSIONS
material
mm
inches
center conductor
solid SPC
(1)
0.29
0.0114
dielectric
solid PTFE
(2)
0.84
0.033
inner shield
SPC
(1)
braid
1.30
0.051
outer shield
-
-
-
jacket
brown FEP
(3)
1.80
0.071
ElECTRICal ChaRaCTERISTICS
characteristic impedance
50Ω ± 2Ω
operating frequency range
DC - 3 GHz
shielding effectiveness
40 dB
voltage withstanding
2 000 V rms
peak power
1 kW
capacitance
100 pF / m
30 pF / ft
velocity of propagation
70 % (4.8 ns / m)
mEChaNICal ChaRaCTERISTICS
recommended minimum
bending radius
9 mm
0.354 inch
weight
8 g / m
0.0053 Ibs / ft
ENVIRONmENTal ChaRaCTERISTICS
operating temperature range
-55 / +200 °C
-67 / +392 °F
fire resistance
yes (CSA FT6 / IEC 332-2)
halogen free
no
fREqUENCy / aTTENUaTION (typ.) /
CW maX pOWER (sea level / 25 °C)
GHz
dB / m
dB / ft
Watts
0.1
0.42
0.13
253
0.2
0.59
0.18
179
0.3
0.72
0.22
146
0.5
0.94
0.28
113
1.0
1.34
0.41
80
1.5
1.65
0.50
65
2.0
1.92
0.58
57
2.5
2.16
0.65
51
3.0
2.37
0.72
46
attenuation calculation (dB/m)
(1.30 x √f GHz) + (0.04 x f GHz)
power calculation (W)
80 / √f GHz
(1)
SPC = Silver Plated Copper
(2)
PTFE = PolyTetraFluoroEthylene
(3)
FEP = Fluorinated Ethylene Propylene
Based on MIL-C17/93 US standard, this cable is
used where non magnetic aspect is required.
In addition the solid inner conductor allows
reduced attenuation in comparison with
standard RG178.
The insulation and jacket materials allow this
cable to be used in severe thermal conditions.
APPLICATION NOTE
flEXIblE CablE 2/50 S
(non magnetic RG178 type)
p/N: C291 140 087
(MIL-C-17/93-RG178)