Cable assemblies, Corrugated cable 1/2, Semi-rigid cable .047 – Northern Connectors Radiall RF & Microwave Cable Assemblies User Manual
Page 27: Cellflex 1/2" spiral), Copper), Construction / dimensions, Electrical characteristics, Mechanical characteristics, Environmental characteristics
www.radiall.com
B-28
CONSTRUCTION / DImENSIONS
material
mm
inches
center conductor
solid AlCC
(1)
3.60
0.142
dielectric
foam PE
(2)
8.30
0.327
corrugated inner shield
spiral copper tube
12.30
0.484
outer shield
-
-
-
jacket
black LSZH PE
(3)
13.50
0.531
ElECTRICal ChaRaCTERISTICS
characteristic impedance
50Ω ± 1Ω
operating frequency range
DC - 11.7 GHz
shielding effectiveness
110 dB
voltage withstanding
5 845 V rms
peak power
20.5 kW
capacitance
82 pF / m
24.8 pF / ft
velocity of propagation
82 % (4.1 ns / m)
mEChaNICal ChaRaCTERISTICS
recommended minimum
bending radius
32.0 mm
1.260 inch
weight
210 g / m
0.140 lbs / ft
ENVIRONmENTal ChaRaCTERISTICS
operating temperature range
-40 / +85 °C
-40 / +185 °F
fire resistance
yes (UL 1581 VW1 / IEC 332-1)
halogen free
yes (IEC 754-2)
fREqUENCy / aTTENUaTION (typ. / 25 °C) /
CW maX pOWER (sea level / 40 °C)
GHz
dB / m
dB / ft
Watts
0.5
0.08
0.02
1 120
1.0
0.11
0.03
770
1.5
0.14
0.04
616
2.0
0.16
0.05
525
2.5
0.18
0.06
461
3.0
0.20
0.06
417
4.0
0.24
0.07
353
6.0
0.30
0.09
278
8.0
0.36
0.11
234
10.0
0.42
0.13
204
attenuation calculation (dB/m)
(0.10 x √f GHz) + (0.01 x f GHz)
(1)
AlCC = Aluminum Covered Copper
(2)
PE = PolyEthylene
(3)
LSZH PE = Low Smoke Zero Hallogen PolyEthylene
The outer conductor of this cable is constituted
of a corrugated tube (spiral winding).
This construction allows perfect shielding and
bendability while respecting large bending radius.
The foam dielectric provides excellent loss and
low return loss levels.
This cable will be advised for feeder and jumper
assemblies in cellular networks as well as
applications requiring high performance level
on long distances.
The anti-UV LSZH (Low Smoke Zero Hallogen)
material is also flame retardant and allows this
cable to be used for indoor public areas as well
as outoor installations.
APPLICATION NOTE
CORRUgaTED CablE 1/2"
(Cellflex 1/2" Spiral)
p/N: C291 994 170
(Cellflex HCF 1/2" CuH-50 AlCu)
This is the smallest semi-rigid cable size
proposed by RADIALL.
Its reduced size allows it to be easily
handformable during integration operations.
APPLICATION NOTE
Cable assemblies
SEmI-RIgID CablE .047
(Copper)
Note: typical attenuation for a couple of connectors (dB) = 0.045 x √f (GHz)
CONSTRUCTION / DImENSIONS
material
mm
inches
center conductor
solid SPCCS
(1)
0.29
0.011
dielectric
solid PTFE
(2)
0.94
0.037
inner shield
copper tubing
1.19
0.047
outer shield
-
-
-
jacket
-
-
-
ElECTRICal ChaRaCTERISTICS
characteristic impedance
50Ω ± 2.5Ω
operating frequency range
DC - 20 GHz
shielding effectiveness
110 dB
voltage withstanding
2 000 V rms
peak power
1.1 kW
capacitance
100 pF / m
30 pF / ft
velocity of propagation
70 % (4.8 ns / m)
mEChaNICal ChaRaCTERISTICS
recommended minimum
bending radius
3.17 mm
0.125 inch
weight
6.0 g / m
0.0040 lbs / ft
ENVIRONmENTal ChaRaCTERISTICS
operating temperature range
-40 / +100 °C
-40 / +212 °F
fire resistance
not applicable
halogen free
no
fREqUENCy / aTTENUaTION (typ.) /
CW maX pOWER (sea level / 25 °C)
GHz
dB / m
dB / ft
Watts
1.0
1.14
0.35
30
2.0
1.64
0.50
21
3.0
2.03
0.61
17
6.0
2.93
0.89
12
8.0
3.43
1.04
11
10.0
3.88
1.18
9.5
12.4
4.37
1.32
8.5
18.0
5.39
1.63
7.1
20.0
5.72
1.73
6.7
attenuation calculation (dB/m)
(1.10 x √f GHz) + (0.04 x f GHz)
power calculation (W)
30 / √f GHz
(1)
SPCCS = Silver Plated Copper Covered Steel
(2)
PTFE = PolyTetraFluoroEthylene
p/N: C291 855 001
(MIL-C-17/151-00001)