www.radiall.com

B-19

CONSTRUCTION / DImENSIONS

material

mm

inches

center conductor

stranded SPC

(1)

0.98

0.039

dielectric

solid PTFE

(2)

2.95

0.116

inner shield

SPC

(1)

braid

-

-

outer shield

SPC

(1)

braid

4.19

0.165

jacket

brown FEP

(3)

4.95

0.195

ElECTRICal ChaRaCTERISTICS

characteristic impedance

50Ω ± 2Ω

operating frequency range

DC - 12.4 GHz

shielding effectiveness

65 dB (DC - 3 GHz)

voltage withstanding

5 000 V rms

peak power

3.4 kW

capacitance

97 pF / m

29.3 pF / ft

velocity of propagation

70 % (4.8 ns / m)

mEChaNICal ChaRaCTERISTICS

recommended minimum

bending radius

20 mm

0.79 inch

weight

66 g / m

0.0442 lbs / ft

ENVIRONmENTal ChaRaCTERISTICS

operating temperature range

-55 / +200 °C

-67 / +392 °F

fire resistance

yes (CSA FT6 / IEC 332-2)

halogen free

no

fREqUENCy / aTTENUaTION (typ.) /

CW maX pOWER (sea level / 25 °C)

GHz

dB / m

dB / ft

Watts

0.5

0.36

0.11

665

1.0

0.52

0.16

470

1.5

0.65

0.20

384

2.0

0.76

0.23

332

3.0

0.95

0.29

271

6.0

1.42

0.43

192

8.0

1.68

0.51

166

10.0

1.92

0.58

149

12.4

2.19

0.66

133

attenuation calculation (dB/m)

(0.48 x √f GHz) + (0.04 x f GHz)

power calculation (W)

470 / √f GHz

(1)

SPC = Silver Plated Copper

(2)

PTFE = PolyTetraFluoroEthylene

(3)

FEP = Fluorinated Ethylene Propylene

Due to its stranded inner conductor, RG 400
is much more flexible than RG142 and RG223.
This cable will be chosen instead
of equivalent RG's for specific applications
requiring high flexibility
Usable in severe thermal conditions.

APPLICATION NOTE

flEXIblE CablE 5/50 D

(RG400)

p/N: C291 324 007

(MIL-C-17/128-RG400)

CONSTRUCTION / DImENSIONS

material

mm

inches

center conductor

stranded SPC

(1)

0.92

0.036

dielectric

solid PTFE

(2)

2.95

0.116

inner shield

SPC braid

-

-

outer shield

SPC braid

4.34

0.171

jacket

Translucent Fiber Glass

5.10

0.201

ElECTRICal ChaRaCTERISTICS

characteristic impedance

50Ω ± 2.5Ω

operating frequency range

DC - 8 GHz

shielding effectiveness

65 dB (DC - 3 GHz)

voltage withstanding

5 000 V rms

peak power

3 kW

capacitance

95 pF / m

28.8 pF / ft

velocity of propagation

70 % (4.8 ns / m)

mEChaNICal ChaRaCTERISTICS

recommended minimum

bending radius

30 mm

1.181 inch

weight

70 g / m

0.0466 lbs / ft

ENVIRONmENTal ChaRaCTERISTICS

operating temperature range

-55 / +200 °C

-67 / +392 °F

fire resistance

yes (IEC 60332-1)

halogen free

no

fREqUENCy / aTTENUaTION (typ. / 25 °C) /

CW maX pOWER (sea level / 40 °C)

GHz

dB / m

dB / ft

Watts

0.5

0.33

0.10

375

1.0

0.48

0.14

260

1.5

0.60

0.18

210

2.0

0.70

0.21

180

2.5

0.80

0.24

160

3.0

0.89

0.27

146

4.0

1.05

0.32

126

5.0

1.20

0.37

112

6.0

1.35

0.41

102

8.0

1.61

0.49

88

attenuation calculation (dB/m)

(0.427 x √f GHz) + (0.05 x f GHz)

(1)

SPC = Silver Plated Copper

(2)

PTFE = PolyTetraFluoroEthylene

Relevant standard: NF-C-93/550-KX23 (France)
Due to its stranded inner conductor it is much
more flexible than RG142 or RG223.
This cable will be chosen instead of equivalent
RG's for specific applications requiring high
flexibility.
Usable in severe thermal conditions.

APPLICATION NOTE

flEXIblE CablE 5/50 D

(KX23)

p/N: C291 322 017

(NF-C-93/550-KX23)

Cable assemblies

: Service+ program = fast delivery

Note: typical attenuation for a couple of connectors (dB) = 0.045 x √f (GHz)