Cable assemblies, Semi-rigid cable .141, Silvered copper) – Northern Connectors Radiall RF & Microwave Cable Assemblies User Manual
Page 33: Non magnetic), Construction / dimensions, Electrical characteristics, Mechanical characteristics, Environmental characteristics
www.radiall.com
B-34
CONSTRUCTION / DImENSIONS
material
mm
inches
center conductor
solid SPC
(1)
0.92
0.036
dielectric
solid PTFE
(2)
2.98
0.117
inner shield
SPC
(1)
tubing
3.58
0.141
outer shield
-
-
-
jacket
-
-
-
ElECTRICal ChaRaCTERISTICS
characteristic impedance
50Ω ± 1Ω
operating frequency range
DC - 20 GHz
shielding effectiveness
110 dB
voltage withstanding
5 000 V rms
peak power
3.4 kW
capacitance
89 pF / m
27 pF / ft
velocity of propagation
70 % (4.8 ns / m)
mEChaNICal ChaRaCTERISTICS
recommended minimum
bending radius
1.90 mm
0.075 inch
weight
46 g / m
0.0309 lbs / ft
ENVIRONmENTal ChaRaCTERISTICS
operating temperature range
-40 / +125 °C
-40 / +257 °F
fire resistance
not applicable
halogen free
no
fREqUENCy / aTTENUaTION (typ.) /
CW maX pOWER (sea level / 25 °C)
GHz
dB / m
dB / ft
Watts
1.0
0.34
0.10
315
2.0
0.50
0.15
223
3.0
0.64
0.19
182
6.0
0.97
0.30
129
8.0
1.17
0.35
111
10.0
1.35
0.41
100
12.4
1.55
0.47
89
18.0
1.99
0.60
74
20.0
2.14
0.65
70
attenuation calculation (dB/m)
(0.30 x √f GHz) + (0.04 x f GHz)
power calculation (W)
315 / √f GHz
(1)
SPC = Silver Plated Copper
(2)
PTFE = PolyTetraFluoroEthylene
Based on RG402 standard, this cable is used
where non magnetic aspect is required.
In addition, due to the outer conductor
coating (silver), this cable will be used
instead of RG402 for applications requiring
high corrosion resistance and improved
solderability.
APPLICATION NOTE
Cable assemblies
SEmI-RIgID CablE .141
(Silvered copper)
CONSTRUCTION / DImENSIONS
material
mm
inches
center conductor
solid SPC
(1)
0.92
0.036
dielectric
solid PTFE
(2)
2.98
0.117
inner shield
copper tubing
3.58
0.141
outer shield
-
-
-
jacket
-
-
-
ElECTRICal ChaRaCTERISTICS
characteristic impedance
50Ω ± 1Ω
operating frequency range
DC - 20 GHz
shielding effectiveness
110 dB
voltage withstanding
5 000 V rms
peak power
3.4 kW
capacitance
89 pF / m
27 pF / ft
velocity of propagation
70 % (4.8 ns / m)
mEChaNICal ChaRaCTERISTICS
recommended minimum
bending radius
2.54 mm
0.100 inch
weight
46 g / m
0.0309 lbs / ft
ENVIRONmENTal ChaRaCTERISTICS
operating temperature range
-40 / +125 °C
-40 / +257 °F
fire resistance
not applicable
halogen free
no
fREqUENCy / aTTENUaTION (typ.) /
CW maX pOWER (sea level / 25 °C)
GHz
dB / m
dB / ft
Watts
1.0
0.34
0.10
315
2.0
0.50
0.15
223
3.0
0.64
0.19
182
6.0
0.97
0.30
129
8.0
1.17
0.35
111
10.0
1.35
0.41
100
12.4
1.55
0.47
89
18.0
1.99
0.60
74
20.0
2.14
0.65
70
attenuation calculation (dB/m)
(0.30 x √f GHz) + (0.04 x f GHz)
power calculation (W)
315 / √f GHz
(1)
SPC = Silver Plated Copper
(2)
PTFE = PolyTetraFluoroEthylene
Based on RG402 standard, this cable is used
where non magnetic aspect is required.
APPLICATION NOTE
SEmI-RIgID CablE .141
(Non magnetic)
p/N: C291 861 061
p/N: C291 861 066
Note: typical attenuation for a couple of connectors (dB) = 0.045 x √f (GHz)