Note: typical attenuation for a couple of connectors (dB) = 0.045 x √f (GHz)
Cable assemblies
CONSTRUCTION / DImENSIONS
material
mm
inches
center conductor
solid AlCC
(1)
2.60
0.102
dielectric
foam PE
(2)
6.30
0.248
corrugated inner shield
spiral copper tube
9.10
0.358
outer shield
-
-
-
jacket
black LSZH PE
(3)
10.20
0.402
ElECTRICal ChaRaCTERISTICS
characteristic impedance
50Ω ± 1Ω
operating frequency range
DC - 13.4 GHz
shielding effectiveness
110 dB
voltage withstanding
4 500 V rms
peak power
11.9 kW
capacitance
82 pF / m
24.8 pF / ft
velocity of propagation
82 % (4.1 ns / m)
mEChaNICal ChaRaCTERISTICS
recommended minimum
bending radius
25.0 mm
0.984 inch
weight
120 g / m
0.080 lbs / ft
ENVIRONmENTal ChaRaCTERISTICS
operating temperature range
-40 / +85 °C
-40 / +185 °F
fire resistance
yes (UL 1581 VW1 / IEC 332-1)
halogen free
yes (IEC 754-2)
fREqUENCy / aTTENUaTION (typ. / 25 °C) /
CW maX pOWER (sea level / 40 °C)
GHz
dB / m
dB / ft
Watts
0.5
0.09
0.03
810
1.0
0.13
0.04
560
1.5
0.17
0.05
449
2.0
0.19
0.06
384
3.0
0.24
0.07
306
4.0
0.29
0.09
260
6.0
0.36
0.11
205
8.0
0.43
0.13
173
10.0
0.49
0.15
152
12.4
0.56
0.17
133
attenuation calculation (dB/m)
(0.123 x √f GHz) + (0.01 x f GHz)
(1)
AlCC = Aluminum Covered Copper
(2)
PE = PolyEthylene
(3)
LSZH PE = Low Smoke Zero Hallogen PolyEthylene
The outer conductor of this cable is constituted
of a corrugated tube (spiral winding).
This construction allows perfect shielding and
bendability while respecting large bending
radius.
The foam dielectric provides excellent loss and
low return loss levels.
This cable will be advised for feeder and
jumper assemblies in cellular networks as well
as applications requiring high performance
level on long distances.
The anti-UV LSZH (Low Smoke Zero Hallogen)
material is also flame retardant and allows
this cable to be used for indoor public areas
as well as outoor installations.
APPLICATION NOTE
CORRUgaTED CablE 1/4"
(Cellflex 1/4" Spiral)
CORRUgaTED CablE 3/8"
(Cellflex 3/8" Spiral)
p/N: C291 996 170
(Cellflex HCF 3/8" CuH-50 AlCu)
CONSTRUCTION / DImENSIONS
material
mm
inches
center conductor
solid AlCC
(1)
1.90
0.075
dielectric
foam PE
(2)
4.30
0.169
corrugated inner shield
spiral copper tube
6.50
0.256
outer shield
-
-
-
jacket
black LSZH PE
(3)
7.80
0.307
ElECTRICal ChaRaCTERISTICS
characteristic impedance
50Ω ± 1Ω
operating frequency range
DC - 20.4 GHz
shielding effectiveness
110 dB
voltage withstanding
3 100 V rms
peak power
5.5 kW
capacitance
82 pF / m
24.8 pF / ft
velocity of propagation
82 % (4.1 ns / m)
mEChaNICal ChaRaCTERISTICS
recommended minimum
bending radius
25.0 mm
0.984 inch
weight
70 g / m
0.047 lb / ft
ENVIRONmENTal ChaRaCTERISTICS
operating temperature range
-40 / +85 °C
-40 / +185 °F
fire resistance
yes (UL 1581 VW1 / IEC 332-1)
halogen free
yes (IEC 754-2)
fREqUENCy / aTTENUaTION (typ. / 25 °C) /
CW maX pOWER (sea level / 40 °C)
GHz
dB / m
dB / ft
Watts
1.0
0.19
0.06
339
2.0
0.27
0.08
232
3.0
0.34
0.10
185
4.0
0.40
0.12
156
6.0
0.51
0.15
124
8.0
0.60
0.18
104
10.0
0.69
0.21
91
12.4
0.78
0.24
79
18.0
0.99
0.30
63
20.0
1.06
0.32
59
attenuation calculation (dB/m)
(0.17 x √f GHz) + (0.015 x f GHz)
(1)
AlCC = Aluminum Covered Copper
(2)
PE = PolyEthylene
(3)
LSZH PE = Low Smoke Zero Hallogen PolyEthylene
The outer conductor of this cable is
constituted of a corrugated tube (spiral
winding).
This construction allows perfect shielding and
bendability while respecting large bending
radius.
The foam dielectric provides excellent loss and
low return loss levels.
This cable will be advised for feeder and
jumper assemblies in cellular networks as well
as applications requiring high performance
level on long distances.
The anti-UV LSZH (Low Smoke Zero Hallogen)
material is also flame retardant and allows
this cable to be used for indoor public areas
as well as outoor installations.
APPLICATION NOTE
p/N: C291 993 170
(Cellflex HCF 1/4" - 50 AlCu)