Cable assemblies, Flexible cable 5/50 s, Flexible cable 5/50 d – Northern Connectors Radiall RF & Microwave Cable Assemblies User Manual
Page 15: Rg58 - kx15), Rg142), Construction / dimensions, Electrical characteristics, Mechanical characteristics, Environmental characteristics
www.radiall.com
B-16
CONSTRUCTION / DImENSIONS
material
mm
inches
center conductor
stranded TC
(1)
0.90
0.035
dielectric
solid PE
(2)
2.95
0.116
inner shield
TC
(1)
braid
3.66
0.144
outer shield
-
-
-
jacket
black PVC
(3)
4.95
0.195
ElECTRICal ChaRaCTERISTICS
characteristic impedance
50Ω ± 2Ω
operating frequency range
DC - 1 GHz
shielding effectiveness
40 dB
voltage withstanding
5 000 V rms
peak power
2.6 kW
capacitance
96 pF / m
29 pF / ft
velocity of propagation
66 % (5 ns / m)
mEChaNICal ChaRaCTERISTICS
recommended minimum
bending radius
20 mm
0.787 inch
weight
35 g / m
0.0234 Ibs / ft
ENVIRONmENTal ChaRaCTERISTICS
operating temperature range
-40 / +85 °C
-40 / +185 °F
fire resistance
no
halogen free
no
fREqUENCy / aTTENUaTION (typ.) /
CW maX pOWER (sea level / 25 °C)
GHz
dB / m
dB / ft
Watts
0.05
0.14
0.04
246
0.1
0.20
0.06
174
0.2
0.29
0.09
123
0.3
0.36
0.11
100
0.5
0.47
0.14
78
0.6
0.51
0.16
71
0.7
0.56
0.17
66
0.8
0.60
0.18
61
1.0
0.67
0.20
55
attenuation calculation (dB/m)
(0.63 x √f GHz) + (0.04 x f GHz)
power calculation (W)
55 / √f GHz
(1)
TC = Tinned Copper
(2)
PE = PolyEthylene
(3)
PVC = PolyVinyl Chloride
CONSTRUCTION / DImENSIONS
material
mm
inches
center conductor
solid SPCCS
(1)
0.94
0.037
dielectric
solid PTFE
(2)
2.95
0.116
inner shield
SPC
(3)
braid
-
-
outer shield
SPC
(3)
braid
4.19
0.165
jacket
brown FEP
(4)
4.95
0.195
ElECTRICal ChaRaCTERISTICS
characteristic impedance
50Ω ± 2Ω
operating frequency range
DC - 12.4 GHz
shielding effectiveness
65 dB (DC - 3GHz)
voltage withstanding
5 000 V rms
peak power
3.4 kW
capacitance
97 pF / m
29.3 pF / ft
velocity of propagation
70 % (4.8 ns / m)
mEChaNICal ChaRaCTERISTICS
recommended minimum
bending radius
25 mm
0.984 inch
weight
64 g / m
0.043 Ibs / ft
ENVIRONmENTal ChaRaCTERISTICS
operating temperature range
-55 / +200 °C
-67 / +392 °F
fire resistance
yes (CSA FT6 / IEC 332-2)
halogen free
no
fREqUENCy / aTTENUaTION (typ.) /
CW maX pOWER (sea level / 25 °C)
GHz
dB / m
dB / ft
Watts
0.5
0.30
0.09
665
1.0
0.44
0.13
470
1.5
0.55
0.17
384
2.0
0.65
0.20
332
3.0
0.81
0.25
271
6.0
1.22
0.37
192
8.0
1.45
0.44
166
10.0
1.66
0.50
149
12.4
1.90
0.58
133
attenuation calculation (dB/m)
(0.40 x √f GHz) + (0.04 x f GHz)
power calculation (W)
470 / √f GHz
(1)
SPCCS = Silver Plated Copper Covered Steel
(2)
PTFE = PolyTetraFluoroEthylene
(3)
SPC = Silver Plated Copper
(4)
FEP = Fluorinated Ethylene Propylene
RG142 is one of the most popular RG cables.
This cable presents a good compromise
between flexibility and electrical performances.
RG142 will be selected among other 5/50 RG's
for applications requiring high frequency range
and low attenuation.
Usable in severe thermal conditions.
RG58 is one of the most popular RG cables.
Due to its construction and raw materials
construction, RG58 / KX15 is far to be as
performant as the equivalent 5/50 cables
( RG142, RG223, ECO142 )
However, this very flexible cable must be
considered for applications requiring low
electrical performance and reduced cost.
APPLICATION NOTE
APPLICATION NOTE
Cable assemblies
flEXIblE CablE 5/50 S
(RG58 - KX15)
flEXIblE CablE 5/50 D
(RG142)
p/N: C291 320 007
(MIL-C-17/158-RG142)
p/N: C291 305 000
(MIL-C-17/28-RG58)
p/N: C291 305 010
(NF-C-93/550-KX15)
: Service+ program = fast delivery
Note: typical attenuation for a couple of connectors (dB) = 0.045 x √f (GHz)