www.radiall.com

B-17

: Service+ program = fast delivery

Note: typical attenuation for a couple of connectors (dB) = 0.045 x √f (GHz)

Cable assemblies

lOW lOSS flEXIblE CablE

5/50 D

(ECO142: alternative to RG142)

CONSTRUCTION / DImENSIONS

material

mm

inches

center conductor

solid OFC

(1)

copper

0.95

0.037

dielectric

foam PE

(2)

2.85

0.112

inner shield

Al

(3)

foil

3.10

0.122

outer shield

TC

(4)

braid

3.50

0.138

jacket

black LSZH PE

(5)

4.50

0.177

ElECTRICal ChaRaCTERISTICS

characteristic impedance

50Ω ± 2Ω

operating frequency range

DC - 3 GHz

shielding effectiveness

80 dB (DC - 3 GHz)

voltage withstanding

5 000 V rms

peak power

2.7 kW

capacitance

87 pF / m

26.4 pF / ft

velocity of propagation

77 % (4.3 ns / m)

mEChaNICal ChaRaCTERISTICS

recommended minimum

bending radius

15 mm

0.590 inch

weight

36 g / m

0.0242 lbs / ft

ENVIRONmENTal ChaRaCTERISTICS

operating temperature range

-40 / +85 °C

-40 / +185 °F

fire resistance

yes (UL1581 VW1 / IEC 332-1)

halogen free

yes (IEC 754-2)

fREqUENCy / aTTENUaTION (typ.) /

CW maX pOWER (sea level / 25 °C)

GHz

dB / m

dB / ft

Watts

0.1

0.12

0.04

411

0.2

0.18

0.05

291

0.3

0.22

0.07

237

0.5

0.28

0.09

184

1.0

0.41

0.12

130

1.5

0.50

0.15

106

2.0

0.58

0.18

92

2.5

0.66

0.20

82

3.0

0.73

0.22

75

attenuation calculation (dB/m)

(0.385 x √f GHz) + (0.02 x f GHz)

power calculation (W)

130 / √f GHz

(1)

OFC = Oxygen Free Copper

(2)

PE = PolyEthylene

(3)

Al = Aluminum

(4)

TC = Tinned Copper

(5)

LSZH PE = Low Smoke Zero Halogen PolyEthylene

Designed by RADIALL, ECO142 is an
advantageous alternative solution to RG142:

• Advantageous in term of electrical
performance:

its optimized construction allows

better attenuation and screening effectiveness
than RG142.

• Advantageous in term of environmental
aspect:

halogen and sulphur free, this cable

does not emit any toxic substance when
submitted to fire.
The flame retardant jacket allows ECO142 to
meet fire resistance standards.

• Advantageous in term of price:

ECO142 design

has integrated all RADIALL knowledge to reach
the best performances with a very competitive
price.
ECO142 is UL style 1375 approved.

This cable is compatible with a large range of
connector series.

ECO-Friendly cable
Cost effective solution

APPLICATION NOTE

p/N: C291 325 290

lOW lOSS flEXIblE

CablE 5/50 D

(ECO142X)

CONSTRUCTION / DImENSIONS

material

mm

inches

center conductor

solid SPC

(1)

0.95

0.037

dielectric

X foam PE

(2)

2.98

0.117

inner shield

SPC

(1)

braid

3.64

0.143

outer shield

SPC

(1)

braid

4.30

0.169

jacket

black with blue stripe

LSZH PE

(3)

5.00

0.197

ElECTRICal ChaRaCTERISTICS

characteristic impedance

50Ω ± 2Ω

operating frequency range

DC - 6 GHz

shielding effectiveness

75 dB (DC - 5 GHz)

voltage withstanding

5 000 V rms

capacitance

94.5 pF / m

28.7 pF / ft

velocity of propagation

71 % (4.7 ns / m)

mEChaNICal ChaRaCTERISTICS

recommended minimum

bending radius

30 mm

1.18 inch

weight

60 g / m

0.0433 Ibs / ft

ENVIRONmENTal ChaRaCTERISTICS

operating temperature range

-40 / +105 °C

-40 / +221 °F

fire resistance

yes (UL1581 VW1 / IEC 332-1)

halogen free

yes (IEC 754-2)

fREqUENCy / aTTENUaTION (typ.) /

CW maX pOWER (sea level / 25 °C)

GHz

dB / m

dB / ft

Watts

0.5

0.36

0.11

354

1.0

0.54

0.16

250

1.5

0.69

0.21

204

2.0

0.83

0.25

177

2.5

0.95

0.29

158

3.0

1.07

0.32

144

3.5

1.18

0.36

134

4.0

1.29

0.39

125

5.0

1.50

0.45

112

6.0

1.70

0.51

102

attenuation calculation (dB/m)

(0.44 x √f GHz) + (0.103 x f GHz)

power calculation (W)

250 / √f GHz

(1)

SPC = Silver Plated Copper

(2)

X foam PE = Crosslink foam PolyEthylene

(3)

LSZH PE = Low Smoke Zero Halogen PolyEthylene

Designed by RADIALL, ECO142X is an
advantageous alternative solution to ECO142
when higher power level is required:
• Advantageous in term of electrical
performance:

the crosslink foam polyethylene

used as dielectric material allows higher
temperature level (thus power range) than
ECO142.
• Advantageous in term of environmental
aspect:

halogen and sulphur free, this cable

does not emit any toxic substance when
submitted to fire. The flame retardant jacket
allows ECO142X to meet fire resistance
standards.
• Advantageous in term of price:

ECO142X

design has integrated all RADIALL knowledge
to reach the best performances with a very
competitive price.
ECO142X is UL style 1375 and 3651 approved.
This cable is compatible with a large range
of standard connector series.

ECO-Friendly cable
Cost effective solution

APPLICATION NOTE

p/N: C291 320 180