beautypg.com

Inspection/setup – Multiquip DCA180SSIU User Manual

Page 33

background image

DCa180SSI/DCa180SSIu 60 hz gen/ • operaTIon anD parTS manual — rev. #1 (08/02/10) — page 33

of the battery fluid is 1.28 (at 68° F). If the specific gravity

should fall to 1.245 or lower, it indicates that the battery is

dead and needs to be recharged or replaced.
Before charging the battery with an external electric source,

be sure to disconnect the battery cables.

Battery Cable Installation

alWaYS be sure the battery cables (Figure 35) are

properly connected to the battery terminals as shown below.

The

red cable is connected to the positive terminal of the

battery, and the

black cable is connected to the negative

terminal of the battery.

Figure 35. Battery Connections

When connecting battery do the following:
1.

never connect the battery cables to the battery

terminals when the

mpeC Control Switch is in either

the

manual position. alWaYS make sure that the

mpeC Control Switch is in the oFF/reSeT position

when connecting the battery.

2. Place a small amount of battery terminal treatment

compound around both battery terminals. This will

ensure a good connection and will help prevent

corrosion around the battery terminals.

CauTIon

alWaYS disconnect the negative terminal FIrST and

reconnect negative terminal

laST.

NOTICE

If the battery cable is connected incorrectly, electrical

damage to the generator will occur. Pay close attention to

the polarity of the battery when connecting the battery.

CauTIon

Inadequate battery connections may cause poor

starting of the generator, and create other malfunctions.

alTernaTor

The polarity of the alternator is negative grounding type.

When an inverted circuit connection takes place, the

circuit will be in short circuit instantaneously resulting the

alternator failure.
Do noT put water directly on the alternator. Entry of water

into the alternator can cause corrosion and damage the

alternator.

WIrIng

Inspect the entire generator for bad or worn electrical wiring

or connections. If any wiring or connections are exposed

(insulation missing) replace wiring immediately.

pIpIng anD hoSe ConneCTIon

Inspect all piping, oil hose, and fuel hose connections for

wear and tightness. Tighten all hose clamps and check

hoses for leaks.
If any hose (

fuel or oil) lines are defective replace them

immediately.

inspectiOn/setUp