OPERAtIOn

STARTiNG THE ENGiNE

1. Place one foot on the trowel’s platform, grab ahold of

any part of the frame, lift yourself onto the trowel, then

sit down in the operator’s seat.

2. The right foot pedal (Figure 10) controls blade and

engine speed. The position of the foot pedal determines

the blade speed. Slow blade speed is obtained by

slightly depressing the pedal. Maximum blade speed

is obtained by fully depressing the pedal.

Figure 10. Blade Speed Control Foot Pedal

NOTICE

This trowel is equipped with a safety stop switch that

will not allow the engine to start unless an operator is

sitting in the operator’s seat. The weight of an operator

depresses an electrical switch, which allows the engine

to start.

wARNiNG

NeveR disable or disconnect the safety stop switch. It is

provided for the operator’s safety, and injury may result

if it is disabled, disconnected or improperly maintained.

NOTICE

Using the safey stop switch to stop the engine after

every use will verify that the switch is working properly.

Remember to turn the key to the “

OFF” position after

stopping the machine. Not doing so may drain the battery.

3. If starting a cold engine, pull the

choke knob

(Figure 11) upward to the “

ClOSEd” position.

Figure 11. Choke Knob (Closed Position)

4. Insert the ignition key (Figure 12) into the ignition

switch.

Figure 12. Ignition Switch

5. Turn the ignition key clockwise to the ON position. Aux1,

Aux 2, coolant temp and oil indicator lamps will light

for 10 seconds (Figure 12). Charge indicator lamp will

remain lit until engine starts.

Figure 13. Indicator Lights

CLOSED

(PULL)

CHOKE

KNOB

OFF

START

ON

NOTICE

The

oil and charge, indicator lights come on when the

ignition switch is in the

ON position, and the engine is

NOT running.