beautypg.com

Maintenance – Multiquip PRO12E53 User Manual

Page 29

background image

PRO12 HYDRAULIC MIXER • OPERATION MANUAL — REV. #1 (06/04/14) — PAGE 29

MAINTENANCE

HYDRAULIC OIL FILTER

Replace hydraulic oil filter (Figure 32) every 500 hours.

Hydraulic tank capacity is 12 gallons (45 liters). Refill with

Shell Tellius 46 hydraulic oil or equivalent.

Figure 32. Hydraulic Oil Filter

MIXER CLEANING

It is important that the drum interior is free of dried material.

Obstructions can cause the paddle blades to lock against

the drum resulting in sudden dump handle movement.
1. Stop the engine. Push the Start/Stop switch on the

engine cover inward to the “

OFF” position.

2. Place the hydraulic paddle lever in "neutral" position

to disengage.

3.

ALWAYS disconnect the spark plug wire or disconnect

electrical power source before cleaning the inside of

the drum.

4. Place "Do Not Operate" tag on mixer.
5. Make sure the rear section of safety grate is connected

to the mixing drum.

6. At the end of each day’s operation, place mixer drum in

an upright position and spray inside of tub immediately

with water to prevent lumps of dried mortar or plaster

from forming and contamination of future batches.

DO

NOT allow a buildup of materials to form on the blades

or anywhere inside the drum.

7. Rotate mixer to dump position and remove debris.
8. Thoroughly clean the entire mixer, cabinet, and frame.

9.

NEVER pour or spray water over the engine or electric

motor (Figure 33).

Figure 33. No Spraying of Water

10. When cleaning of the entire mixer is done, return mixing

drum to an upright position.

MIXER STORAGE

For storage of the mixer for over 30 days, the following is

recommended:
1. Drain the fuel tank completely, or add STA-BIL to the

fuel.

2. Run the engine until the fuel is completely consumed.
3. Completely drain used oil from the engine crankcase

and fill with fresh clean oil, then follow the procedures

described in the engine manual for engine storage.

4. Clean the entire mixer and engine compartment.
5. Place the mixing drum in the down position (mouth

facing downward).

6. Cover the mixer and place it a clean dry area, that is

protected from harsh elements.

This manual is related to the following products: