pAgE 40 — ga6HB/ga6HeB 60 hz gENERATOR• OpERATiON ANd pARTs mANuAl — REv. #0 (03/13/14)

Ga6Hb/Ga6Heb— namePlaTe anD DeCals assy.

S-1123

To avoid injury,
you MUST read
and understand
operator’s manual
before using this
machine.

Ask for training

as needed.

This machine to

be operated by

qualified

personnel only.

WARNING

Only qualified personnel should

install, use or service this

equipment.

DANGEROUS

GAS

S-4984

WARNING

Only operate machine in well ventilated

areas.

DO NOT inhale exhaust gases.

Only qualified personnel should

install, use or service this

equipment.

S-4985

DANGER

Do not touch output terminals or

internal wiring while unit is operating.

Turn off power before servicing.

Only qualified personnel should

install, use or service this

equipment.

ELECTRICAL

SHOCK

HAZARD

CAUTION

OPERATE AT

3600 RPM ONLY

(

)

FULL THROTTLE

DAMAGE MAY RESULT IF

OPERATED AT LOWER SPEEDS

WARNING

B e f o r e c o n n e c t i n g t h i s

g e n e r a t o r t o a n y b u i l d i n g ’ s

e l e c t r i c a l s y s t e m , a l i c e n s e d

e l e c t r i c i a n m u s t i n s t a l l a n

i s o l a t i o n ( t r a n s f e r ) s w i t c h .

S e r i o u s i n j u r y o r d e a t h m a y

r e s u l t w i t h o u t t h i s t r a n s f e r

s w i t c h .

A91110010

DANGER

Using a generator indoors

.

Utilser un générateur à l’ intérieur VOUS TUERA EN QUELQÙES MINUTES.

CAN KILL YOU IN MINUTES

120

V

O

F

F

GAC-2.2H

POWERED by
Honda Engines

120V

15A

GR PRISE DE

TERRE

AC CIRCUIT BREAKER

INTERRUPTEUR DE

COURANT PRINCIPAL

NEUTRALBONDED TO FRAME

NEUTRE MISA LA MASSEA

LA CARCASSE DU MOTEUR

211052

120

V

O

F

F

GAC-2.2H

POWERED by
Honda Engines

120V

15A

GR PRISE DE

TERRE

AC CIRCUIT BREAKER

INTERRUPTEUR DE

COURANT PRINCIPAL

NEUTRAL BONDED TO FRAME

NEUTRE MISA LA MASSEA

LA CARCASSE DU MOTEUR

211052

120

V

O

F

F

GAC-2.2H

POWERED by
Honda Engines

120V

15A

GR PRISE DE

TERRE

AC CIRCUIT BREAKER

INTERRUPTEUR DE

COURANT PRINCIPAL

NEUTRALBONDED TO FRAME

NEUTRE MISA LA MASSEA

LA CARCASSE DU MOTEUR

211052

NEVER use in enclosed or partially

enclosed areas.

Utilisation INTERDITE dans un

espace clos ou partiellement clos.

ONLY use outdoors and away from

open windows, doors, and vents.

Utilisation UNIQUEMENT à l’ extér leur

portes et trous d’ aération

Exhaust contains carbon monoxide, a poison gas you cannot see or smell.

Les gaz d’ échappement contiennent du monoxyde de carbon, un gaz toxique

invisible et inodore.

A90400001

GROUND ROD

FOR EARTH

GROUND

CONNECT TO

BUILDING

GROUND

IF REQUIRED

8 FT. MINIMUM

REFERENCE

NEC 250-52(C)

AC CIRCUIT

BREAKER

120/240V

30A

120V

30A

20A

20A

0N

OFF

IDLE

CONTROL

OPERATION

SWITCH

ON

OFF

FULL POWER

SWITCH

120V

120V/240V

120

V

OFF

21A

GA-6H

6000

GROUND

SCREW

GROUND

CABLE

#8 MINIMUM

DANGER

THE POSSIBILITY EXISTS OF

IF

GENERATOR/WELDER IS NOT PROPERLY GROUNDED.

ALWAYS CONNECT EARTH GROUND (GROUND

ROD) TO GENERATOR GROUND POINT.

ELECTROCUTION

FOR FURTHER GROUNDING

INSTRUCTIONS, READ MANUAL

D9531100104

WARNING

Operation of this equipment may create

sparks that can start fires around dry

vegetation.

A spark arrestor may be required.

The operator should contact local fire

agencies for laws or regulation relating

to fire prevention requirements.

A91110010

3

6

ON

ON

S-3704

FUEL COCK

8

1. Before starting check the oil and fuel level.

2. Switch the circuit breaker to the “OFF” position.

3. Open the fuel valve.

4.

5. Turn the operation switch to the “ON” position

6. After the engine starts, gradually push in the choke knob.

7. Run the generator for 3-5 minutes without load.

8. Check for any abnormal noise or smell.

9. Switch the circuit breaker to the “ON” position.

10.When stopping, cut-off the load and allow the unit

to cool for 2-3 minutes before stopping engine.

11.Turn the operation switch to the “OFF” position.

12. After the engine completely stops, close the fuel valve.

Pull the choke knob.

and push the start button to start the engine.

OPERATING INSTRUCTIONS

A55100000

1

1. Before starting check the oil and fuel level.

2. Switch the circuit breaker to the “OFF” position.

3. Open the fuel valve.

4.

5. Turn the operation switch to the “ON” position.

6. Pull the recoil starter.

. After the engine starts, gradually push in the choke knob.

8. Run the generator for 3-5 minutes without load.

9. Check for any abnormal noise or smell.

10.Switch the circuit breaker to the “ON” position.

11.When stopping, cut-off the load and allow the unit

to cool for 2-3 minutes before stopping engine.

12.Turn the operation switch to the “OFF” position.

13. After the engine completely stops, close the fuel valve.

Pull the choke knob.

7

OPERATING INSTRUCTIONS

A92120010

GA6HB

GA6HEB

2

CLEAN ELEMENT EVERY 50 HOURS (EVERY

10 HOURS UNDER DUSTY CONDITIONS.

WASH IN HIGH FLASH-POINT SOLEVENT

SQUEEZE DRY, THE DIP IN CLEAN ENGINE

OIL AND SQUEEZE OUT EXCESS OIL.

AIR CLEANER MAINTENANCE

10

14

GA-6H

11

120/240V

30A

0N

OFF

IDLE

CONTROL

GA-6HEB

120

20A

120

30A

AC CIRCUIT BREAKER

GFCI PROTECTED

AC VOLTMETER

120V

FULL POWER

SWITCH

120V

120V/240V

120 V

20A

120 V

20A

IN SIMULTANEOUS USE 30 AMP MAX

A51120230

0N

OFF

OPERATION

SWITCH

START SWITCH

120/240V

30A

0N

OFF

IDLE

CONTROL

OPERATION

SWITCH

ON

OFF

GA-6HB

120

20A

120

30A

AC CIRCUIT BREAKER

GFCI PROTECTED

AC VOLTMETER

120V

FULL POWER

SWITCH

120V

120V/240V

120 V

20A

120 V

20A

IN SIMULTANEOUS USE 30 AMP MAX

A511202002

S-2090

S-2091

15

12

13

16

BATTERY

CAPACITY

12V 26 Ah

CONNECTION (+) STARTER

(-) EARTH

KEEP COVER ON THE BATTERY

WHEN DURING OPERATION.

S-1237

4

5

7

120/240V

30A

0N

OFF

IDLE

CONTROL

120

V

GA-6HEB

120

20A

120

30A

AC CIRCUIT BREAKER

GFCI PROTECTED

120

AC VOLTMETER

120V

FULL POWER

SWITCH

120V

120V/240V

MANUAL RESET

P

O

W

E

R

F

A

U

L

T

120 V

20A

120 V

20A

IN SIMULTANEOUS USE 30 AMP MAX

ELECTRIC START

START

SWITCH

OPERATION

SWITCH

9