beautypg.com

Operation – Multiquip GA-6HEB User Manual

Page 22

background image

page 22 — ga6HB/ga6HeB 60 hz gENERATOR• OpERATiON ANd pARTs mANuAl — REv. #0 (03/13/14)

oPeRaTion

This section is intended to assist the operator with the initial

start-up of the portable generator. It is extremely important

that this section be read carefully before attempting to use

the generator in the field.

Before starting the Engine

1. Be sure to disconnect all electrical loads from the

generator prior to starting the engine.

2.

NEvER start the engine with the main circuit breaker

in the

ON position. Always place circuit breaker (Figure 12)

in the

OFF position before starting.

Figure 12. Main Circuit Breaker (OFF)

starting the Engine (Recoil start)

1. Place the engine fuel valve lever (Figure 13) in the

ON

position.

Figure 13. Engine Fuel Valve Lever (ON)

2. Place the choke lever (Figure 14) in the

ClOsEd

position if starting a cold engine.

NOTICE

Both model generators are equipped with a GFCI

sensing module. The purpose of this module is to

sense a ground fault during operation of the generator

and shut down the generator once the ground fault has

been detected.
Multiquip recommends that the GFCI sensing module

be tested before each use of the generator. Reference

the maintenance section of this manual for the testing

of the GFCI sensing module.

ON

OFF

Figure 14. Choke Lever

3. Place the choke lever (Figure 14) in the

OpeN position

if starting a warm engine or the temperature is warm.

4. Place the generator's operation switch (Figure 15) in

the

ON position.

Figure 15. Operation Switch (ON)

5. If your generator is a recoil start only (no battery), grasp

the starter grip (Figure 16) and slowly pull it out. The

resistance becomes the hardest at a certain position,

corresponding to the compression point. Pull the starter

grip briskly and smoothly for starting.
Proceed to step 6 if your unit is an electric start model

(battery installed).

Figure 16. Starter Grip

ON

OFF

GA-6HB

GA-6HEB

ON

NOTICE

dO NOT pull the starter rope all the way to the end.
dO NOT release the starter rope after pulling. Allow it

to rewind as soon as possible..