oPeRaTion

6. Press the generator's pushbutton start switch

(Figure 17) and listen for the engine to start.

Figure 17. Start Switch (GA6HEB Only)

7. If the engine has started, slowly return the choke lever

(Figure 14) to the

OpeN position. If the engine has not

started repeat steps 1 through 6.

8. Before the generator is placed into operation, run the

engine for 3-5 minutes. Check for abnormal smells,

fuel leaks, and noises that would associate with lose

components.

9. Place idle control switch (Figure 18) in the

OFF

position. This will allow the engine speed to run at about

3600 RPM's.

Figure 18. Idle Control Switch (OFF)

OFF

ON

OFF

GA-6HB

GA-6HEB

NOTICE

Placing the idle control switch in the

OFF position

(Figure 18) allows the engine to operate at a maximum

speed of about 3600 RPM's.
When the idle control switch (Figure 19) is placed in the

up position (

ON), the generator will run at idle speed

(2200 RPM's) until a load is applied, at that time the

engine speed will increase to 3600 RPM's as long as

a load is being applied.
When the load is not in use, the engine speed will drop

back to the idle mode after about 3 seconds.

Figure 19. Idle Control switch (ON)

10. Place main circuit breaker (Figure 20) in the

ON

position.

Figure 20. Main Circuit Breaker (ON)

11. Read voltmeter on front panel of generator (Figure 21)

and verify that 120 VAC is displayed. Using an external

voltmeter as shown in Figure 19, verify that 120 VAC

is present at the 120V twist-lock and GFCI duplex

receptacles.

Figure 21. 120V Twist-Lock/GFCI Receptacles

ON

OFF

GA-6HB

GA-6HEB

ON

OFF

ON

120V

OFF

V~

V

300 mV

A

A~

V

COM

120 VAC

GFCI

L5-30R

120

V

G

W

120VAC

X