Stopping The Engine

Normal Shutdown

1. Move throttle lever quickly from the FULL OPEN to IDLE

position (Figure 9) and run the engine for three minutes at
low speed. After the engine

cools

, turn the engine

start/stop

switch to the “OFF” position (Figure 6) until engine comes
to a complete stop.

2. Close the fuel shut- off valve by moving the fuel cock lever to

the CLOSED position. See Figure 5

Emergency Showdown

1. Move the throttle lever quickly to the

IDLE

position, and turn

the engine ON/OFF switch (Figure 6) to the

STOP

position.

CAUTION:

CAUTION:

CAUTION:

CAUTION:

CAUTION:

Make sure that the throttle lever is moved to the
FULL OPEN position. Operating the rammer at
less than full speeds can result in damage to
the clutch springs or foot

Figure 9. Throttle Lever

2. The MT-85HS Tamping rammer is designed to run at 5,000

rpm. At optimum rpm the foot hits at the rate of 690 impacts
per minute. Increasing throttle speed past factory set rpm
does not increase impacts and may damage unit. The MT-
85HS is designed to advance while tamping. For faster
advance, pull back slightly on the handle so that rear of foot
contacts soil first.

7.

If the carburetor is flooded or the crankcase is loaded with
excess fuel, open the drain plug as shown in (Figure 8) and
drain out excess fuel.

Figure 8. Drain Plug

Operation

1. To start the rammer tamping action, move the throttle lever

(Figure 9) quickly from IDLE (close) to the FULL OPEN
position . DO NOT move the throttle lever slowly as this may
cause damage to the clutch or spring.