Damper System Operation

Routine Maintenance

47

.

Calendar time

Daily

1
week

1
month

2
months

3
months

6
months

1
year

2
year

5 +
years

Running time - Hours

8

40

160

320

500

1000

2,000

4,000

10,000

Hazard labels

Inspect for
legibility

X

Replace as
required

-

Hydraulic Hoses

Inspect for
leaks and
wear

X

Replace

MTS

Hydraulic Fluid

Sensory
Check

X

Particle count

MTS

Analyze for
contamination

MTS

Load Frame

Set initial
accumulator
check interval

X

Check
accumulator
N

2

precharge

X

Clean actuator
rod and
columns

X

Inspect
actuator for
leakage

X

Adjust
Servovalve
mechanical
null

After the valve balancing
procedure (electrical
compensation) has been
completed and the results are
judged unsatisfactory.

Change
servovalve
filter.

When servovalve performance has
deteriorated.