g) Loop the cable down and back. Plug it into the enclosure switch connector.

In most cases where the test area enclosure is installed after frame installation, it will be necessary to
remove a jumper plug first. Do not discard the jumper plug. Keep the jumper plug in case the test area
enclosure is removed in the future. The machine requires either the jumper plug or the test area
enclosure to function.

15. Insert two M6 x 1 mm x 35 mm sockethead screws (item 2) through the top two holes of the back panel.

16. Position the back panel up against the two side panels such that the screws go into the threaded holes in

the side panels and hand-tighten.

17. Install the remaining two screws and tighten the four screws enough to hold the panel firmly in place, but

not so tight the panel cannot be slightly positioned for alignment.

18. If necessary, push the panels in place such that the tops are all aligned.

The door can be slightly adjusted. To adjust the door, loosen the screw that secures the side panel to the
top bracket, and pull or push the top of the side panel to raise or lower the handle side of the door so the
top of the door aligns with the side panel.

19. When the side panels, back panel, and door are all aligned, snug all fasteners according to the following

table.

Torque Guidelines

Torque to

Item

11 N-m (8.2 lb-ft)

A

10 N-m (7.3 lb-ft)

B

12 N-m (8.8 lb-ft)

C

6.5 N-m (4.8 lb-ft)

D

MTS Acumen™ Electrodynamic Test System 9

Test Area Enclosure Installation