MTS Hydraulic Power Unit Model 506-92 User Manual
Page 8

Introduction 1-4
Table 1-2. HPU Specifications (Continued)
Parameter
Model 506.82B
Model 506.92B
Supercharge pump motor power rating
25 hp (19 kW)
40 hp (30 kW)
3-phase current 460V/60 Hz:
†
Inrush
575 A
775 A
Continuous
395 A
535 A
Starter type
Wye-delta
Wye-delta
24 V external hydraulic control amps (with optional
remote control)
6.8 A
6.8 A
Maximum cooling water heat load:
BTU per hour
760,000
1,020,000
Kilocalories per hour
192,000
257,600
Atmospheric heat load
(BTU per hour)
56,900
87,800
Atmospheric heat load
(Kilocalories per hour)
14,400
22,200
Water inlet/outlet size
1.5 in. (38 mm) NPT
2 in. (51 mm) NPT
Maximum ambient operating temperature
104
°
F (40
°
C)
104
°
F (40
°
C)
Minimum ambient operating temperature
40
°
F (4.4
°
C)
40
°
F (4.4
°
C)
Height with casters
78 in. (1981 mm)
78 in. (1981 mm)
Length
111 in. (2819 mm)
111 in. (2819 mm)
Width
68 in. (1727 mm)
68 in. (1727 mm)
Weight with oil
12,500 lb (5669 kg)
12,500 lb (5669 kg)
*
The number of connections are shown in parentheses.
†
Currents listed are typical theoretical values based on data outlined in the NEPA-70 (national
electrical code). Supply conductors and disconnect switch sizing must be done using the
customer’s local and state codes.