Maintenance, Maintenance 37 – MTS Series 247 Actuators User Manual
Page 37

Series 247 Actuators
Maintenance
37
Maintenance
The Series 247 Actuators is designed for extended periods of operation without
extensive maintenance requirements.
The following table lists the recommended interval for each of these procedures.
Maintenance Intervals
*
*
The interval is based on an 8 hour a day, 5 days a week operation schedule. Dusty or dirty environments
require more frequent maintenance.
What to Do
When to Do It
How to do it
Clean the actuator
Every 40 hours of continuous
operation or weekly.
Clean exposed areas of the actuator piston
rod with a clean, dry, lint free rag.
If the actuator is continually exposed to a
dirty operating environment, clean the
piston rod on a daily basis.
Inspect the actuator for
wear
Monthly.
Inspect the actuator piston rod and seals for
excessive wear and/or leakage.
Small scratches in the axial direction of the
piston rod or polishing of the rod surface is
considered normal operating wear.
Replace the actuator
seals
Yearly or sooner if the actuator
inspection show excessive
leakage.
Arrange service with MTS Systems
Corporation.