T11-a s – Metal Sales T6-A User Manual
Page 10
![background image](/manuals/567708/10/background.png)
PEF-10
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11
800.406.7387 (Corporate Office) • www.metalsales.us.com
E
xposEd
F
astEnEd
p
anEl
s
EriEs
T11-a s
eCTion
P
roPerTies
and
l
oad
T
ables
C
34
1
/
8
" Coverage
4
7
/
8
" Pitch
3
/
4
"
1
5
/
8
"
1
5
/
8
"
1
3
/
4
"
3
/
4
"
ALLOWABLE UNIFORM LOADS PSF
(3 or More Equal Spans)
5’ 6’ 7’ 8’ 10’ 12’ 5’ 6’ 7’ 8’ 10’ 12’
SECTION PROPERTIES
Bottom in Compression
Width
(in.)
Yield
KSI
34.125" 50
34.125" 50
34.125" 33
34.125" 33
24
Ga.
22
20
18
Sxx
In
3
/ft
Ixx
In
4
/ft
Weight
PSF
1.18
1.56
1.85
2.43
Top in Compression
Sxx
In
3
/ft
Ixx
In
4
/ft
0.1067
0.1207
0.0713
0.0829 76 53 39 30 19 12 93 65 48 37 21 12
0.1533
0.1519
0.1033
0.1259 116 81 60 46 28 16 139 97 72 55 28 16
0.1967
0.2029
0.1367
0.1792 108 75 56 43 27 19 121 85 63 48 31 19
0.2633
0.2697
0.2033
0.2483 149 104 77 59 38 25 161 113 84 64 41 25
Inward
Load
Outward / Uplift
Load
1. Theoretical section properties have been calculated per AISI 2001 “Specification for the Design of Cold-formed Steel Structural Members.” Ixx and Sxx are
effective section properties for deflection and bending.
2. Allowable load is calculated in accordance with AISI 2001 specifications considering bending, shear, combined bending and shear, deflection, and applicable
testing when available. Allowable load considers the worst case of 3 and 4 equal span conditions. Allowable load does not address web crippling or
fasteners/support connection and panel weight is not considered.
3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.
4. Allowable loads do not include a 1/3 stress increase in uplift.
Substructure
Coverage
Length
Fasteners
Availability
GENERAL INFORMATION
T11-A Panels are designed to be utilized over open
structural framing or a solid substrate.
T11-A Panels are available in a 1
3
/
4
" depth with a coverage
width of 34
1
/
8
".
Minimum factory cut length is 5'-0".
Maximum panel length is 30'-0".
The fastener selection guide should be consulted for
choosing the proper fastener for specific applications.
Quantity and type of fastener must meet necessary
loading and code requirements.
NOTE: All panels are subject to surface distortion due to
improperly applied fasteners. Overdriven fasteners will
cause stress and induce oil canning across the face of the
panel at or near the point of attachment.
Finishes: Kynar 500 (PVDF) standard; optional: multi-pass
Kynar, Marblique, Plastisol, Polyester, and
MS Colorfast45
®
(SMP)
Gauges: 24 ga, 22 ga, 20 ga, and 18 ga
#12-14 Self Driller
#12-14 Self Driller
1
/
4
"-14 x
7
/
8
" Stitch Screw
Tape Sealant
#12-14 Self Driller
Tape Sealant
1
/
4
"-14 x
7
/
8
" Stitch Screw
Tape Sealant
1
/
4
"-14 x
7
/
8
" Stitch Screw
ATTACHMENT DETAIL
FASTENING PATTERN
Ends of Panel
Field of Panel