PEF-10

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

E

xposEd

F

astEnEd

p

anEl

s

EriEs

T11-a s

eCTion

P

roPerTies

and

l

oad

T

ables

C

34

1

/

8

" Coverage

4

7

/

8

" Pitch

3

/

4

"

1

5

/

8

"

1

5

/

8

"

1

3

/

4

"

3

/

4

"

ALLOWABLE UNIFORM LOADS PSF

(3 or More Equal Spans)

5’ 6’ 7’ 8’ 10’ 12’ 5’ 6’ 7’ 8’ 10’ 12’

SECTION PROPERTIES

Bottom in Compression

Width

(in.)

Yield

KSI

34.125" 50
34.125" 50
34.125" 33
34.125" 33

24

Ga.

22
20
18

Sxx

In

3

/ft

Ixx

In

4

/ft

Weight

PSF

1.18
1.56
1.85
2.43

Top in Compression

Sxx

In

3

/ft

Ixx

In

4

/ft

0.1067

0.1207

0.0713

0.0829 76 53 39 30 19 12 93 65 48 37 21 12

0.1533

0.1519

0.1033

0.1259 116 81 60 46 28 16 139 97 72 55 28 16

0.1967

0.2029

0.1367

0.1792 108 75 56 43 27 19 121 85 63 48 31 19

0.2633

0.2697

0.2033

0.2483 149 104 77 59 38 25 161 113 84 64 41 25

Inward

Load

Outward / Uplift

Load

1. Theoretical section properties have been calculated per AISI 2001 “Specification for the Design of Cold-formed Steel Structural Members.” Ixx and Sxx are

effective section properties for deflection and bending.

2. Allowable load is calculated in accordance with AISI 2001 specifications considering bending, shear, combined bending and shear, deflection, and applicable

testing when available. Allowable load considers the worst case of 3 and 4 equal span conditions. Allowable load does not address web crippling or

fasteners/support connection and panel weight is not considered.

3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.

4. Allowable loads do not include a 1/3 stress increase in uplift.

Substructure

Coverage

Length

Fasteners

Availability

GENERAL INFORMATION

T11-A Panels are designed to be utilized over open

structural framing or a solid substrate.

T11-A Panels are available in a 1

3

/

4

" depth with a coverage

width of 34

1

/

8

".

Minimum factory cut length is 5'-0".

Maximum panel length is 30'-0".

The fastener selection guide should be consulted for

choosing the proper fastener for specific applications.

Quantity and type of fastener must meet necessary

loading and code requirements.

NOTE: All panels are subject to surface distortion due to

improperly applied fasteners. Overdriven fasteners will

cause stress and induce oil canning across the face of the

panel at or near the point of attachment.

Finishes: Kynar 500 (PVDF) standard; optional: multi-pass

Kynar, Marblique, Plastisol, Polyester, and

MS Colorfast45

®

(SMP)

Gauges: 24 ga, 22 ga, 20 ga, and 18 ga

#12-14 Self Driller

#12-14 Self Driller

1

/

4

"-14 x

7

/

8

" Stitch Screw

Tape Sealant

#12-14 Self Driller

Tape Sealant

1

/

4

"-14 x

7

/

8

" Stitch Screw

Tape Sealant

1

/

4

"-14 x

7

/

8

" Stitch Screw

ATTACHMENT DETAIL

FASTENING PATTERN

Ends of Panel

Field of Panel