Stile, Ul 580 w – Metal Sales Stile Manual User Manual
Page 6
![background image](/manuals/567705/6/background.png)
Underwriters Laboratories Inc.
®
UL
®
LISTED
PST-6
STILE
®
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11
800.406.7387 (Corporate Office) • www.metalsales.us.com
1. Metal Roof Deck Panels* No. 26 MSG min thick coated steel. Width 39.4 in., height at ribs 1-3/16 in.
METAL SALES MANUFACTURING CORPORATION - “Stile”
2. Cover Board (Optional)-1/4 in. Georgia-Pacific “Dens- Deck”.
3. Underlayment 30 lb organic felt. Sides overlapped min 2 in., end laps per manufacturer’s instructions.
4. Insulation* (Optional)-Any UL Classified rigid insulation, thickness not to exceed 3-1/2 in.
5. Fasteners (Screws) Fasteners to be No. 14-14 x 1-1/2 in., hex head, Type AB, self- tapping screws with sealing washer and painted
finish.
5A. Fasteners (Rivets) Fasteners used to attach panels (Item 1) at side and end laps to be 1/8 in. diameter by 3/16 in. long stainless
steel pop rivets.
6. Plywood Decking Decking to be min 5/8 in. (19/32 in. actual) thick. APA 20 span rated plywood sheathing. Fastened to supports
with No. 8 by 2 in. long coarse thread wood screws.
All butt joints to be sealed against leakage by using tape and/or caulk or with one-part urethane sealant.
7. Supports (Joists) Spaced max 2 ft OC. Graded dimension lumber, No. 2 or better.
Refer to general information, Roof Deck Construction, for Items not evaluated.
*Bearing the UL Classification Marking
Ul 580 w
ind
U
PlifT
i
nformaTion
Construction No. 533
November 11, 1999
Uplift - Class 90
Fire Not Investigated
STILE
1
2
3
5
6
7
1
2
3
5A
6
5
36" o.c.
5"
4