beautypg.com

Stile, Ul 580 w – Metal Sales Stile Manual User Manual

Page 6

background image

Underwriters Laboratories Inc.

®

UL

®

LISTED

PST-6

STILE

®

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

1. Metal Roof Deck Panels* No. 26 MSG min thick coated steel. Width 39.4 in., height at ribs 1-3/16 in.

METAL SALES MANUFACTURING CORPORATION - “Stile”

2. Cover Board (Optional)-1/4 in. Georgia-Pacific “Dens- Deck”.

3. Underlayment 30 lb organic felt. Sides overlapped min 2 in., end laps per manufacturer’s instructions.

4. Insulation* (Optional)-Any UL Classified rigid insulation, thickness not to exceed 3-1/2 in.

5. Fasteners (Screws) Fasteners to be No. 14-14 x 1-1/2 in., hex head, Type AB, self- tapping screws with sealing washer and painted

finish.

5A. Fasteners (Rivets) Fasteners used to attach panels (Item 1) at side and end laps to be 1/8 in. diameter by 3/16 in. long stainless

steel pop rivets.

6. Plywood Decking Decking to be min 5/8 in. (19/32 in. actual) thick. APA 20 span rated plywood sheathing. Fastened to supports

with No. 8 by 2 in. long coarse thread wood screws.

All butt joints to be sealed against leakage by using tape and/or caulk or with one-part urethane sealant.

7. Supports (Joists) Spaced max 2 ft OC. Graded dimension lumber, No. 2 or better.

Refer to general information, Roof Deck Construction, for Items not evaluated.

*Bearing the UL Classification Marking

Ul 580 w

ind

U

PlifT

i

nformaTion

Construction No. 533

November 11, 1999

Uplift - Class 90

Fire Not Investigated

STILE

1

2

3

5

6

7

1

2

3

5A

6

5

36" o.c.

5"

4