Snap-loc 24 – Metal Sales Snap-Loc 24 Manual User Manual
Page 13
![background image](/manuals/567701/13/background.png)
PSN-13
SNAP-LOC 24
®
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11
800.406.7387 (Corporate Office) • www.metalsales.us.com
d
esign
/ i
nsTallaTion
C
onsideraTions
(
ConT
)
Panel Endlapping - If panel endlapping is required, endlaps are to be applied in one continuous line. This allows the cinch straps
to complete full coverage of the Snap-Loc 24 Panel.
OPTIONAL PANEL:
Optional when endlapping panels
Used as both the eave and peak panel
Both ends factory notched and punched
STANDARD PANEL:
Standard if endlapping of panels is not required
No punching
No notching
Optional Panels
Notched/Punched
Eave
Factory Notched / Punched Panels - Unless otherwise specified, Metal Sales provides all Snap-Loc 24 panels with no factory rib
notching or fastener hole punching. Panels that are to be factory notched/punched must be specified at time of order.
Eave Panel
Peak Panel
Panel Lap
Endlap Purlin
Panel Installation Sequence
1
2
4
6
8
3
5
7
Peak