Operation and control
Up to a duration of 23 hours 59 minutes, the time is displayed in hh:mm
(hours:minutes) format. For 24 hours and more, the format dd:hh (days:hours) is
used. The maximum duration adjustable is 99 days 00 hours.
3. Press the confirmation key to confirm.
Hauptschalter
>
Zu der Typenbezeichnung gibt es momentan drei Entwurfsrichtungen,
ich kann Ihnen noch nicht sagen, ob Memmert hierzu schon eine Entscheidung
getroffen hat.
Die hier gezeigt Variante, ist die von uns empfohlene Richtung.
UF 110
PLUS
ON
344
.4
444
4
.
TEMP
Set
°C
°C
FLAP
40
%
TIMER
h
d
10
02
End
Sept.
29
22 24
FAN
%
0
%
100
ALARM
max
444
.4°C
auto
+/-
0.0
K
min
444
.4°C
O
O
ON
N
N
N
O
O
N
O
Manu
44.Sept
The display now shows the remaining time
in a large font and the approximate end time
in a smaller font beneath. The status display
shows "Timer active".
TIMER
30
m
04
h
End 13:30 23.11.
Timer active
12.Sept.2012 13:44
4. Now, as described under 5.4.2 , set the individual values which you want the appliance
to operate at. The set values can be changed at any time while the timer elapses. The
changes are effective immediately.
In
Setup
, you can choose if the timer should run setpoint-dependent or not. This
determines whether the timer should not start until a tolerance band around the set
temperature is reached or if it should start right after activation (see page 39). If
the timer runs setpoint-dependent, this is indicated by the
symbol in the timer
display.
When the timer has elapsed, the display shows
00h:00m. All functions (heating etc.) are switched off.
An acoustic alarm sounds, which can be deactivated by
pressing the confirmation key.
To deactivate the timer, open the timer display by
pressing the activation key again and then turning the
turn control to reduce the timer setting until --:-- is
displayed. Confirm with the confirmation key.
5.4.6 Programme mode
In this operating mode, programmes saved in the appliance can be started with different
combinations of individual parameters (temperature, fan speed, interior lighting) at staggered
intervals, which the appliance then automatically processes in sequence. These programmes
are not created directly at the appliance but externally at a computer / laptop and using
AtmoCONTROL software. Transfer to the appliance is possible using the provided USB storage
medium or via Ethernet.
A description of how to create and save programmes can be found in the separate
AtmoCONTROL software manual.
TIMER
00
m
00
h
End 13:30 23.11.
TIMER
--
m
--
h
End 13:30 23.11.