7 limiter, 9400 technology applications | actuator – speed, Parameter setting & configuration limiter – Lenze E94AxHE Technology Application Actuating drive - Speed User Manual
Page 26

9400 Technology applications | Actuator – speed
Parameter setting & configuration
Limiter
26
L
EDS94TA10010xxxx EN 1.1 - 10/2008
4.7
Limiter
[4-9]
Basic function "Limiter" (schematic diagram)
r
Parameter setting: Tab Application parameters dialog level Overview Limiter
The basic function "Limiter", where
applicable, by means of limit switches
monitors travel range limits.
In the case of homing, positioning and
manual jog the basic function "Limiter" if
required provides for the compliance with
kinematic limit values.
LS_ManualJog
n
t
и
з
LS_Brake
n
t
LS_Limiter
n
t
LS_Quickstop
STOP
LS_Speed...
M
Speed
setpoint
n
t
LS_Stop
internal
status machine
DI2
DI6
DI7
DI8
DI1
Status
machine
(basic drive
functions)
Basic drive functions
M
v
и
з
Note!
The parameterised limit values are not effective for the basic functions "speed
follower", "torque follower", and "position follower"!
For the exceeding of the limit values an error response can be set.
Parameter
Lenze setting
Value Unit
Only for homing, positioning and manual jog
C02702
Limitations are active
Deactivated
C02703
Max. speed
3600.0000 unit/s
C02705
Max. acceleration
3600.0000 unit/s
2
C02706
Min. S-ramp time
100 ms
C02707
Permissible direction of rotation
Positive and negative
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
FALSE Positive limit switch
C03150/1
FALSE Negative limit switch
C03150/2