Update of a project from v3.0 to v3.x – Lenze PLC Designer Migration PLC Designer (R2-x)-PLC Designer (R3-x) User Manual
Page 26

Update of a project from V3.0 to V3.x
Updating the project environment
26
Lenze · PLC Designer | Migration of V2.x projects · 1.2 EN - 02/2013
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2. Upgrade the project environment to the current version (ProjectProject Environment):
• Update the following devices added to the device tree to the current version:
L-force Controller 3200
CANopen Manager (if available)
EtherCAT Master (if available)
PROFIBUS Master (if available)
All I/O modules connected to the backplane bus
• It is not required to update further devices.
3. Save project (FileSave project).
4. Clear project (BuildClean all)
5. Generate project (BuildGenerate code)
6. Transfer project to the V3.x target system (OnlineDownload)
7. Exit »PLC Designer« (FileExit)
8. Navigate to the directory where the Windows-specific Documents and Settings are saved
(the drive and name depend on the computer, for example: C:\Documents and Settings\All
Users\Application Data
• Change to the ...\Lenze\PlcDesigner\Devices subdirectory.
• Delete the devicecache.xml file.
9. Restart »PLC Designer«.