Lenze · PLC Designer | Migration of V2.x projects · 1.2 EN - 02/2013
13
General information
Control configuration
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4. The wildcard describes a program:
$Program$.bToggle ??PLC_PRG.bToggle
• This type of wildcard replacement cannot be imported into the »PLC Designer« V3.x. (This
wildcard replacement is only used in exceptional cases.)
5. The wildcard is replaced by different types:
$Var$
Replacement 1 : PLC_PRG.n (INT)
Replacement 2 : PLC_PRG.st (STRING)
• Remedy: Two different wildcards must be defined in the interface.
6. The visualisation is in a library. The wildcards will be replaced later from any project.
• Remedy 1: The TYPE_NONE data types must be replaced manually.
• Remedy 2: The library must be implemented into a project and the wildcard must be replaced
correctly. If this project is then imported, the data type is determined correctly in the library
as well.
Grouping
• Groups and (not yet) available elements cannot be imported into the »PLC Designer« V3.
5.3
Control configuration
The control configuration of a »PLC Designer« V2 project cannot be imported into the »PLC Desig-
ner« V3.
As a consequence...
• the device configuration must be created anew .
• the variables in the control configuration must be declared anew.
5.4
Network variables
• In the »PLC Designer« V3.x, GVL objects are created. The variable declarations can be imported.
• The network properties are not imported.
5.5
Access to the CANopen master or CANopen slave
The access to internal variables of the CANopen master/CANopen slave (e.g. nStatus) via the
global data structures existing in the »PLC Designer«< V2 project is not possible in the »PLC Desig-
ner« V3.
• The access takes place in the »PLC Designer« V3 via function calls of the CiA405 library (new in
V3).
5.6
L-force Motion
5.6.1
AxisGroup not available anymore
The axis groups used in »PLC Designer« V2 are not available in V3.