Parameter setting
6-15
BA2131EN
Inhibit voltage
xxxx xxxx xxxx xx0x
automatically when
fault reaction is over
Standstill
xxxx xxxx
xxxx x110
Standstill
xxxx xxxx xxxx
x110
Switch on
xxxx xxxx
xxxx x111
automatically when in-
itializing is completed
Reset fault
xxxx xxxx 0xxx xxxx
Switch on unit
Status word xxxx xxxx x0xx 0000
NOT READY TO SWITCH ON
READY TO SWITCH ON
Status word xxxx xxxx x01x 0001
SWITCHED ON
Status word xxxx xxxx x01x 0011
OPERATION ENABLED
Status word xxxx xxxx x01x 0111
Fault
Status word xxxx xxxx x0xx 1000
Example:
Status information by means of “status word“
Bit 15 ... bit 0 (binary display)
SWITCH ON INHIBIT
Status word xxxx xxxx x0xx 0000
QUICK STOP ACTIVE
Status word xxxx xxxx x01x 0111
Operation enable
xxxx xxxx xxxx 1111 and
act. speed value <> 0*
Operation inhibit
xxxx xxxx xxxx 0111 or act.
speed value = 0*
Inhibit RFG is mapped to quick
stop
Quick stop
xxxx xxxx xxxx x01x
Quick stop
xxxx xxxx xxxx x01x
Inhibit voltage
xxxx xxxx xxxx xx0x
Standstill
xxxx xxxx xxxx x110
MALFUNCTION REACTION ACTIVE
Status word xxxx xxxx x0xx 1111
Fault
was
recognized
xxxx xxxx 1xxx xxxx
Inhibit voltage
xxxx xxxx xxxx xx01
or
quick stop completed
9
8
4
5
11
6
7
10
12
14
13
3
Note:
* only effective for 821X, 8200 vector when the
automatic DC-injection brake is active (L-C0106,
L-C2106 <> 0)
2
Fig. 6-4
Status diagram DRIVECOM unit control
Status
Meaning
NOT READY TO SWITCH
ON
The controller is being initialized and is not yet ready to operate. It automatically switches to the status READY TO SWITCH ON.
SWITCH-ON INHIBIT
The controller is inhibited and waits for command 2 (shut down).
READY TO SWITCH ON
The controller is inhibited and waits for command 3 (switch on).
SWITCHED ON
The controller is inhibited and waits for command 4 (enable operation).
OPERATION ENABLED
The controller is enabled. In this status, a pulse inhibit can be set automatically.
FAULT REACTION ACTIVE
A fault (TRIP) was recognized and a fault response initiated.
FAULT
The controller is in the status “FAULT“ (TRIP).
QUICK STOP ACTIVE
While being in the status “OPERATION ENABLED“ the command “quick stop“ was set. The controller is decelerated in a controlled way
(quick-stop ramp). After deceleration, the controller automatically changes to the controller status “SWITCH ON INHIBIT“.