1 process-data assignments for 82xx, 2 process-data assignment for 8200 vector, Process-data assignments for 82xx – Lenze 2131IB User Manual
Page 33: Process-data assignment for 8200 vector, Parameter setting

Parameter setting
6-10
BA2131EN
6.4.1
Process-data assignments for 82XX
Structure of the PO-data response (data to drive)
Byte 1
Byte 2
Byte 3
Byte 4
DRIVECOM control word
High byte
DRIVECOM control word
Low byte
Setpoint
High byte
Setpoint
Low byte
DRIVECOM control word: see chapter 6.5.3 or chapter 6.5.2.
Setpoint: frequency setpoint
Here the frequency setpoint is preselected as process data word. The standardization differs from
C0046. It is indicated with a sign:
б
24000 =
б
480 Hz.
Structure of the PI data response (data from drive)
Byte 1
Byte 2
Byte 3
Byte 4
DRIVECOM status word
High byte
DRIVECOM status word
Low byte
Actual value
High byte
Actual value
Low byte
DRIVECOM status word: see chapter 6.5.4 or chapter 6.5.2.
Actual value: act. frequency value
The actual frequency value is indicated with a sign:
б
24000 =
б
480 Hz.
6.4.2
Process-data assignment for 8200 vector
Structure of the PO data response
Digital and analog input and output signals can be freely configured (see Operating Instructions for
8200 vector; codes C0410, C0412, C0417 and C0421)
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
DRIVECOM
Control word
High byte
DRIVECOM
Control word
Low byte
AIF-IN.W1
High byte
AIF-IN.W1
Low byte
AIF-IN.W2
High byte
AIF-IN.W2
Low byte
Structure of the PI-data response
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
DRIVECOM
Status word
High byte
DRIVECOM
Status word
Low byte
AIF-OUT.W1
High byte
AIF-OUT.W1
Low byte
AIF-OUT.W2
High byte
AIF-OUT.W2
Low byte
Show/Hide Bookmarks