Safety engineering – Lenze E94AYAD - SM300 User Manual
Page 15

Safety engineering
Device modules
Safety module SM300
1
1.2
1.2.3
1.2-5
EDS94AYAD EN 2.2
X82.1
Labelling
Description
n. c.
This terminal strip is not assigned.
n. c.
n. c.
n. c.
n. c.
n. c.
n. c.
n. c.
n. c.
X82.2
Labelling
Description
-
GND external supply
+
24 V external supply via a safely separated power supply unit
(SELV/PELV)
n. c.
This part of the terminal strip is not assigned.
n. c.
n. c.
n. c.
AIE
Error confirmation input (Acknowledge Input Error)
CLA
Clock output for passive sensors, channel A (clock A)
CLB
Clock output for passive sensors, channel B (clock B)
X82.3
Labelling
Description
GCL
GND clock output
GI2
GND IN I2A/I2B
I2B
Sensor input 2, channel B (only for passive sensors)
I2A
Sensor input 2, channel A (only for passive sensors)
GCL
GND clock output
GI1
GND I1A/I1B
I1B
Sensor input 1, channel B (only for passive sensors)
I1A
Sensor input 1, channel A (only for passive sensors)
n. c.
This terminal is not assigned.
X82.4
Labelling
Description
GCL
GND clock output
GI4
GND I4A/I4B
I4B
Sensor input 4, channel B (only for active sensors)
I4A
Sensor input 4, channel A (only for active sensors)
n. c.
This part of the terminal strip is not assigned.
Sensor input 3 is not available.
n. c.
n. c.
n. c.
n. c.
Terminal assignment