Safety engineering, Device modules safety module sm300, 3 elements of the module – Lenze E94AYAD - SM300 User Manual
Page 14

Safety engineering
Device modules
Safety module SM300
1
1.2
1.2.3
1.2-4
EDS94AYAD EN 2.2
1.2.3.3
Elements of the module
SSP94SM317
Fig. 1.2-2
Module view
Pos.
Description
PROFIsafe target address switch (on the left housing side)
X82.1
Pluggable terminal strips for input and output signals
X82.2
X82.3
X82.4
Pos.
Colour
State
Description
MS
Green
On
Drive-based safety is initialised faultlessly.
Blinking
Drive-based safety is initialised faultlessly. Internal
communication to the standard device is not
possible.
Off
Drive-based safety is not initialised.
Acknowledgement is not possible.
EN
Yellow
On
Controller enabled
Off
Non-safe display ”STO”
ME
Red
On
System error:
z
After a serious internal error, STO is activated.
z
Can only be reset by switching the 24V supply.
Blinking
Error:
z
After an internal error or an error at the safe
inputs, a standstill function is activated.
z
The safety class is quit.
z
Acknowledgement is possible.
Flashing
Fault:
z
A monitoring function has responded and
activated a standstill function.
z
The safety class is not quit.
z
Acknowledgement is possible.
Off
Error-free operation
PS
Red
On
Error PROFIsafe:
z
Communication is not possible.
z
Acknowledgement is possible.
Blinking
No valid PROFIsafe configuration
Off
PROFIsafe is error-free.
DE
Red
On
The module is not accepted by the standard device
(see notes given in the documentation for the
standard device).
Displays