beautypg.com

8 diagnostics, Led status displays, Diagnostics – Lenze E94AYCPM User Manual

Page 47

background image

Diagnostics

LED status displays

8

EDK94AYCPM DE/EN/FR/ES/IT 6.0

47

l

H1_Diagnose−KompModul Anzeigeelemente

8

Diagnostics

LED status displays

E94YCIB001F

LED

Description

Pos.

Colour

Condition

MS

Green

On

The communication module is supplied with voltage and
connected to the standard device.

Blinking

The communication module is supplied with voltage, but has no
connection to the standard device. (The standard device is
switched off, initialising, or not present.)

ME

Red

On

An error in the communication module has occurred.

BS

Green

Blinking

Communication via the communication module has been
established. PROFIBUS communication is active.

BE

Red

On

Bus monitoring has been triggered.

DE

Red

On

The communication module is not accepted by the standard
device. (See notes in the documentation for the standard device.)